2016
DOI: 10.1016/j.chemosphere.2015.11.016
|View full text |Cite
|
Sign up to set email alerts
|

(Eco)toxicity and biodegradability of protic ionic liquids

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
42
0
1

Year Published

2017
2017
2021
2021

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 103 publications
(44 citation statements)
references
References 56 publications
1
42
0
1
Order By: Relevance
“…the ILs in this study were moderately toxic (decanoates and isostearates between 10–100 mg/L) or practically harmless (neodecanoates 100–1000 mg/L) according to their EC 50 values. Two EC 50 values, after 5 and 15 minutes incubation, are provided for reference purposes, since either of these incubation times is typically used in previous studies7131415161718192021222324252627282930313233343536373839 utilising V. fischeri bacteria. The toxic effect is time-dependent, particularly with relatively short incubation times (minutes time-scale).…”
Section: Resultsmentioning
confidence: 99%
“…the ILs in this study were moderately toxic (decanoates and isostearates between 10–100 mg/L) or practically harmless (neodecanoates 100–1000 mg/L) according to their EC 50 values. Two EC 50 values, after 5 and 15 minutes incubation, are provided for reference purposes, since either of these incubation times is typically used in previous studies7131415161718192021222324252627282930313233343536373839 utilising V. fischeri bacteria. The toxic effect is time-dependent, particularly with relatively short incubation times (minutes time-scale).…”
Section: Resultsmentioning
confidence: 99%
“…Based on TU values, the compounds can be classified into four categories: i) non-toxic: TU values < 1, ii) toxic: TU values from 1 to 10, iii) very toxic: TU values between 10 and 100, and iv) extremely toxic: TU values > 100 [33,35]. All analytical measurements were performed at least three times.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…Taking into account that bacterial luminescence (light emission) is directly related to cellular respiration, a drop in light emission is caused by a decrease in respiration due to the presence of toxic compounds to the bacteria. In this sense, EC50, i.e., the concentration of IL that reduces the luminescence of bacteria by 50% after 15 min of exposure, was calculated[33]. Additionally, the toxic units (TU) were determined after 15 min of contact time.…”
mentioning
confidence: 99%
“…Because of this feature, many works in the past claimed that they were green solvents, but many ionic liquids are toxic (Latala et al, 2005) and effluents or spills could contaminate aquifers and consequently affect the flora and the fauna present in the enviroment. Studies indicate that ionic liquids based on imidazolium are more toxic than protic ionic liquids (PIL) based on amines and short -chain acids and that the toxicity is related to the hydrophilicity / lipophilicity of the ionic liquid (Peric et al, 2014, Oliveira et al 2016. They are formed by a Bronsted-Lowry acid-base reaction (Drummond and Kennedy, 2009) that, unlike aprotic ionic liquids, have labile protons and are able to form a hydrogen bond network.…”
Section: Introductionmentioning
confidence: 99%