“…Almeida and Muniz improved the zero-sequence power method and used the zero-sequence active power component to determine the fault segment, which was suitable for the arc suppression coil grounding system. However, the method was interfered by the unbalanced current of the current transformer, resulting in low reliability of fault location [4]. e transient zero-mode power direction method proposed by Bhatia is used to calculate the transient zero-mode voltage and current to determine the fault direction and then the field terminal measuring equipment is used to determine the fault section.…”
Section: Literature Reviewmentioning
confidence: 99%
“…Almeida and Muniz improved the zero-sequence power method and used the zero-sequence active power component to determine the fault segment, which was suitable for the arc suppression coil grounding system. However, the method was interfered by the unbalanced current of the current transformer, resulting in low reliability of fault location [4]. e transient zero-mode power direction method proposed by Bhatia is used to calculate the transient zero-mode voltage and current to determine the fault direction and then the field terminal measuring equipment is used to determine the fault section.…”
Section: Literature Reviewmentioning
confidence: 99%
“…The state quantity of uninterrupted power detection can not only reflect the overall state of the transformer from many aspects, but also an important basis for the analysis and diagnosis of the failure mode. Common body faults can be divided into four categories according to their parts: body insulation faults, winding connection faults, winding deformation faults and iron core faults; according to their nature, they can be divided into: thermal faults, electrical faults, deformation faults, moisture and dirt faults [7][8]. According to the information in the table, a simple analysis can be done: the sound frequency band range of bird song and corona discharge sound does not overlap with the sound frequency band range of the transformer body, so it is not necessary to consider it when denoising.…”
Section: Coarse Analysis Of Failure Modesmentioning