2010
DOI: 10.1016/j.clinbiochem.2010.01.002
|View full text |Cite
|
Sign up to set email alerts
|

Effect of hemolysis on insulin determination by the Beckman Coulter Unicell DXI 800 immunoassay analyzer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(7 citation statements)
references
References 8 publications
0
7
0
Order By: Relevance
“…For the appraisal of samples’ long‐term storage stability up to 12 months at −80 °C and −150 °C, FluidX® storage tubes (FluidX Ltd. Monks Heath Hall, Nether Alderley, United Kingdom) were used. The influence of hemolysis was investigated according to Cook et al …”
Section: Methodsmentioning
confidence: 99%
“…For the appraisal of samples’ long‐term storage stability up to 12 months at −80 °C and −150 °C, FluidX® storage tubes (FluidX Ltd. Monks Heath Hall, Nether Alderley, United Kingdom) were used. The influence of hemolysis was investigated according to Cook et al …”
Section: Methodsmentioning
confidence: 99%
“…Four ELISA kits for human insulin (10‐1113‐01, Mercodia; 80‐INSHU‐E01.1, Alpco; KT‐886, Epitope Diagnostics; ab200011, Abcam) were purchased from the respective manufacturers. Three CLIA kits were equipped with fully automated analyzers (Siemens Centaur XP, Siemens Healthineers; Unicel Dxl800, Beckman Coulter Diagnostics; Cobas e801, Roche Diagnostics) including reagents and necessary parts 15–17 . All kits are intended to be used to research and in‐vitro diagnosis depending on regional permission.…”
Section: Methodsmentioning
confidence: 99%
“…Three CLIA kits were equipped with fully automated analyzers (Siemens Centaur XP, Siemens Healthineers; Unicel Dxl800, Beckman Coulter Diagnostics; Cobas e801, Roche Diagnostics) including reagents and necessary parts. [15][16][17] All kits are intended to be used to research and in-vitro diagnosis depending on regional permission. Pooled human serum was obtained from Innovative Research (Canada) followed by homogenization, filtration, and aliquots in-house protocol (Supporting Information).…”
Section: Chemicalsmentioning
confidence: 99%
“…It is possible that different therapeutic molecules and their respective methods may show differences or different risks for such interference. It was discussed that examples had been observed where variations in matrices impacted final bioanalytical concentration values, one example being hemolysis effects on some insulin assays [14,15].…”
Section: Testing For Hemolysis and Lipemia Effects During Lba Methods Validationmentioning
confidence: 99%