2018
DOI: 10.1088/1757-899x/429/1/012101
|View full text |Cite
|
Sign up to set email alerts
|

Effect of infill on tensile and flexural strength of 3D printed PLA parts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
32
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
2

Relationship

0
10

Authors

Journals

citations
Cited by 52 publications
(37 citation statements)
references
References 2 publications
5
32
0
Order By: Relevance
“…Table 3 shows a list of mechanical properties reported for FDM-produced PLA specimens (Ezeh and Susmel, 2019;Khan et al, 2018;Leite et al, 2018;Ouballouch et al, 2018;Tymrak et al, 2014;Wittbrodt and Pearce, 2015;Yao et al, 2019).Tensile strength values in the literature exhibit a very wide range of 19-58 MPa. While most of the data is somewhat close to the bulk strength of PLA, some of the studies reported much lower strength values.…”
Section: Polylactic Acidmentioning
confidence: 99%
“…Table 3 shows a list of mechanical properties reported for FDM-produced PLA specimens (Ezeh and Susmel, 2019;Khan et al, 2018;Leite et al, 2018;Ouballouch et al, 2018;Tymrak et al, 2014;Wittbrodt and Pearce, 2015;Yao et al, 2019).Tensile strength values in the literature exhibit a very wide range of 19-58 MPa. While most of the data is somewhat close to the bulk strength of PLA, some of the studies reported much lower strength values.…”
Section: Polylactic Acidmentioning
confidence: 99%
“…Concentric infill has not yet been tested in compression in the literature, though studies show it exhibits lower strengths in tension and flexion than other infill patterns when printed using acrylonitrile butadiene styrene or polyactic acid composites (Khan et al, 2017(Khan et al, , 2018Kesavarma et al, 2020), a characteristic that may be beneficial for comfort applications. Cross infill has also not been tested in the literature; thus, a formal study of its behaviour is beneficial.…”
Section: Sample Preparation 211 Printing Parametersmentioning
confidence: 99%
“…Tensile tests were carried out at room temperature (20 • C), at a relative humidity of 60%. The test speed was 5 mm/min with nominal initial grip to grip separation of 110 mm for each specimen [33]. The force transducer, with a limit of 20 kN, was used with a mechanical gripping system on a Zwick tensile testing frame.…”
Section: Mechanical and Thermal Characterization Proceduresmentioning
confidence: 99%