Effect of Residual Strength Parameters on FRC Flexural Creep: Multivariate Analysis

Abstract: This paper reports the multivariate analysis of experimental results from more than one hundred FRC prismatic specimens tested under sustained flexural loads for at least 90 days, collected from previously published sources. Principal Component Analysis was used to minimise the number of variables in the modelling process while compromising the minimum amount of information. The creep parameters analysed were the creep coefficients at 14, 30, and 90 days and the corresponding crack opening rates. They were rel… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2016
2016
2020
2020

Publication Types

Select...
1
1
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 10 publications
0
2
0
Order By: Relevance
“…Fortunately, near 70% of creep tests were conducted in a climate room where either temperature of RH could be controlled. Nevertheless, it is clearly stated that temperature control is easier than RH since some creep tests [79,85,86,89,103,107] were reported in controlled temperature, but a considerable scatter in RH where it could be just restricted. Temperature is usually kept constant in values ranging from 19 to 25 ºC, being 20 ºC the most used temperature during the creep test.…”
Section: Short-beam Flexure Creep Test: Prismatic Specimensmentioning
confidence: 99%
See 1 more Smart Citation
“…Fortunately, near 70% of creep tests were conducted in a climate room where either temperature of RH could be controlled. Nevertheless, it is clearly stated that temperature control is easier than RH since some creep tests [79,85,86,89,103,107] were reported in controlled temperature, but a considerable scatter in RH where it could be just restricted. Temperature is usually kept constant in values ranging from 19 to 25 ºC, being 20 ºC the most used temperature during the creep test.…”
Section: Short-beam Flexure Creep Test: Prismatic Specimensmentioning
confidence: 99%
“…This methodology was assessed on 7 FRC series [39,[77][78][79] comprising 39 prismatic tested on flexure creep. Long-term experimental results obtained using the presented methodology [77][78][79][80][81] are included in the state-of-the-art analysis carried out in Chapter 2.…”
Section: Creep Test Proceduresmentioning
confidence: 99%