2015
DOI: 10.1109/tdei.2015.005023
|View full text |Cite
|
Sign up to set email alerts
|

Effects of thermal aging on creepage discharge in oil- impregnated pressboard under combined AC-DC voltage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(15 citation statements)
references
References 18 publications
0
15
0
Order By: Relevance
“…The valve-side windings in a converter transformer withstand the voltage of complex waveforms [5]. The turn-to-ground insulation of the valve-side wingdings withstands pulsating DC voltage [5,6], also known as combined AC-DC voltage or AC and DC combined voltages [7][8][9][10]. The breakdown characteristics of OIP at pulsating DC voltage show many differences compared with that at AC voltage [6].…”
Section: Introductionmentioning
confidence: 99%
“…The valve-side windings in a converter transformer withstand the voltage of complex waveforms [5]. The turn-to-ground insulation of the valve-side wingdings withstands pulsating DC voltage [5,6], also known as combined AC-DC voltage or AC and DC combined voltages [7][8][9][10]. The breakdown characteristics of OIP at pulsating DC voltage show many differences compared with that at AC voltage [6].…”
Section: Introductionmentioning
confidence: 99%
“…The test circuit design was the same as that in Refs. [8,9]. The PD measuring instrument used the pulse current method for measurement; further, the sampling frequency of the system was 5 MHz, and the PD bandwidth was 0.04-1 MHz.…”
Section: Experimental Platformmentioning
confidence: 99%
“…In this study, the interval time ∆t of two adjacent discharges is used instead of the phase φ in the partial discharge under AC voltage. Then, the statistical characteristic spectra are formed by combining the interval time ∆t, partial discharge magnitude Q, and number of discharges n. Time-resolved pulse sequence analysis (TPRSA) was used to study the creepage discharge development process of oil-paper insulation under ADCV [8,9].…”
Section: Creepage Discharge Development Process Of Oil-paper Insulation Under Adcvmentioning
confidence: 99%
See 1 more Smart Citation
“…The unaged is Aging0. After 2000 h, the amount of radiation is about 4160 MJ m −2 , which is equivalent to 28−30 months of UV exposure in the region [23].…”
Section: Ultraviolet Accelerated Aging Devicementioning
confidence: 99%