1996
DOI: 10.1515/bmte.1996.41.s1.194
|View full text |Cite
|
Sign up to set email alerts
|

Ein Verfahren zur in-vivo Kontrolle der Bestrahlungsplanung bei der Schwerionen-Tumortherapie mittels Positronen-Emissions-Tomographie

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2003
2003
2015
2015

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(16 citation statements)
references
References 3 publications
0
16
0
Order By: Relevance
“…Secondly, there are also analogue influences as for the uncompensated simulation since there is a small residual motion within the 4D CT phase. These 2.5 mm (cf table 1) are below the spatial resolution in the mid plane of the PET scanner system which is about 5 mm due to the large detector crystals with a side length of 6.75 mm and the double-head geometry (Lauckner 1999). Anyway, the residual motion might slightly influence the 4D PT-PET images.…”
Section: Comparison With 3d Simulationmentioning
confidence: 94%
See 1 more Smart Citation
“…Secondly, there are also analogue influences as for the uncompensated simulation since there is a small residual motion within the 4D CT phase. These 2.5 mm (cf table 1) are below the spatial resolution in the mid plane of the PET scanner system which is about 5 mm due to the large detector crystals with a side length of 6.75 mm and the double-head geometry (Lauckner 1999). Anyway, the residual motion might slightly influence the 4D PT-PET images.…”
Section: Comparison With 3d Simulationmentioning
confidence: 94%
“…However, since 4D reconstruction algorithms are not the objective of this paper we simply calculate a 3D reconstruction for each of the generated amplitude sorted listmode data streams to verify the simulation results (section 3.2.2). The phase wise applied 3D maximum likelihood expectation maximization (MLEM) algorithm has been developed at Forschungszentrum Dresden-Rossendorf (Lauckner 1999, Hinz 2000, Pönisch et al 2003. Corrections for photon attenuation based on the corresponding CT phase and for the limited solid angle coverage of the scanner have been included.…”
Section: Pt-pet Data Simulation and Evaluationmentioning
confidence: 99%
“…Due to the limited angle geometry, the spatial resolution of the in-beam positron camera is dependent strongly on the position in the field of view. It is around 5 mm in the slice parallel to the detector heads (cf figure 1), 8 mm perpendicular to it and 12 mm off the center of the field of view, respectively (Lauckner 1999). Nevertheless, it has been shown by means of spreading out Bragg peak irradiation that the range resolution at the distal slope of the β + -activity distribution is less than 1 mm for carbon (Hinz 2001), protons (Parodi et al 2005) and for Helium ions (Fiedler et al 2006) in homogeneous targets.…”
Section: Methodsmentioning
confidence: 99%
“…Therefore, an extensive and accurate Monte Carlo simulation taking into account all processes starting with the impinging ions up to the detection of the annihilation γ -rays has been developed (Pönisch et al 2004). Both, measured and simulated β + -activity distribution undergo the same reconstruction process (Lauckner 1999). The evaluation of the irradiation is performed by means of a comparison of reconstructed images representing predicted and measured β + -activity distributions (Enghardt et al 2004a).…”
Section: Introductionmentioning
confidence: 99%
“…These probabilities were calculated using Siddon ray-tracing algorithm (Siddon 1985). In the case of the patient data, the system matrix was assessed using a code developed specifically for this application (Laukner 1999) and the sensitivity matrix was calculated in advance. The time information was modeled within p ij, δT by weighting each LOR by a Gaussian distribution with FWHM equal to the CRT and mean value equal to the expected position of the emission using δT (Groiselle and Glick 2004).…”
Section: Image Reconstructionmentioning
confidence: 99%