2012
DOI: 10.1016/j.elecom.2012.03.007
|View full text |Cite
|
Sign up to set email alerts
|

Electrochemical detection of DNA hybridization by a zirconia modified diamond electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
11
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 21 publications
(11 citation statements)
references
References 24 publications
0
11
0
Order By: Relevance
“…NDs introduced into Caenorhabditis elegans worm did not cause any detectable stress to worms [198]. In mice, intravenous injection of 50 nm NDs led to long-term entrapment in the liver and the lung [195], but no mice showed any abnormal symptoms. Similarly, subcutaneous and intraperitoneal injection of 100 nm NDs in rats led to accumulation of NDs in retention organs over 1 month with no impact on the rats' viability [197].…”
Section: Nds Toxicity and Biodistributionmentioning
confidence: 91%
See 2 more Smart Citations
“…NDs introduced into Caenorhabditis elegans worm did not cause any detectable stress to worms [198]. In mice, intravenous injection of 50 nm NDs led to long-term entrapment in the liver and the lung [195], but no mice showed any abnormal symptoms. Similarly, subcutaneous and intraperitoneal injection of 100 nm NDs in rats led to accumulation of NDs in retention organs over 1 month with no impact on the rats' viability [197].…”
Section: Nds Toxicity and Biodistributionmentioning
confidence: 91%
“…Several long-term in vitro [22,194] and in vivo [195][196][197] previous studies demonstrated that NDs are non-cytotoxic, better tolerated by cells than other nanocarbon materials [198]. NDs introduced into Caenorhabditis elegans worm did not cause any detectable stress to worms [198].…”
Section: Nds Toxicity and Biodistributionmentioning
confidence: 99%
See 1 more Smart Citation
“…Zirconium oxide modified glassy carbon electrode have been used for the detection of various bio molecules such as hemoglobin, cytochrome P450 2B6 and DNA etc. [8][9][10]. To the best of our knowledge, no systematic report is available on the zirconia based voltammetric sensor in solubilized system.…”
Section: Introductionmentioning
confidence: 89%
“…It could be observed that there is decrease in MB oxidation current with increasing concentrations of complementary DNA used for hybridization which may be due to hindrance of the MB: guanine interaction driven by duplex formation. 46 The peak current vary logarithmically with DNA concentration in the range 10 À16 to 10 À6 M (Fig. 7B), following the equation;…”
mentioning
confidence: 99%