Enabling robust quantitative readout in an equipment-free model of device development

Abstract: A critical constraint in the design of appropriate medical devices for the lowest-resource settings is the lack of access to maintenance or repair on instrumentation. There are numerous point-of-care applications for which quantitative readout would have clinical utility. Thus, a challenge to the device developer is to enable quantitative device readout in an equipment-free model that is appropriate for use in even the lowest-resource settings. Paper microfluidics has great potential for enabling equipment-fre… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
38
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 45 publications
(38 citation statements)
references
References 36 publications
0
38
0
Order By: Relevance
“…In the near future, the translation of current research prototypes into commercial applications should mainly address challenges related with quality assurance [3]. One of the most critical aspects to be tackled is the achievement of reproducible quantitative results; this depends not only on the test’s performance and the capability of producing identical sensor batches but also on the environmental variables, which can affect the operating conditions and consequently, the signal output [8]. As such, POCTs are often more at risk of interferences than conventional laboratory assays [6].…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…In the near future, the translation of current research prototypes into commercial applications should mainly address challenges related with quality assurance [3]. One of the most critical aspects to be tackled is the achievement of reproducible quantitative results; this depends not only on the test’s performance and the capability of producing identical sensor batches but also on the environmental variables, which can affect the operating conditions and consequently, the signal output [8]. As such, POCTs are often more at risk of interferences than conventional laboratory assays [6].…”
Section: Discussionmentioning
confidence: 99%
“…The World Health Organization outlined other key words in the research and development of POCTs for the lowest-resource environments. Altogether, they constitute the ASSURED guidelines: Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment-free and Deliverable to end-users [1,4,7,8]. However, regarding the use of POCTs in the developed world, some of these criteria are not quite relevant.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Key advantages include ease of fabrication (storage, transport and use), low reagent volume, porous structure that facilitates capillary flow, and simple signal readout. Several papers reviewed various fabrication methods and applications of the μPADs (Cate et al, 2014;Fu, 2014;Li et al, 2012;Martinez et al, 2010).…”
Section: Introductionmentioning
confidence: 99%
“…Such strategies would reduce the cost of bio-diagnosis, while increasing the portability of the devices that do not require external readout instrumentation [141,142]. One approach to perform equipment-free analysis relies upon color intensity comparators using an external calibration or standard calibration integrated within the device [143,144].…”
Section: Readout Outcomesmentioning
confidence: 99%