1997
DOI: 10.1007/bf02505568
|View full text |Cite
|
Sign up to set email alerts
|

Enantiomeric resolution of persistent compounds of technical toxaphene (CTTs) on t-butyldimethylsilylated β-cyclodextrin phases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

2
46
0

Year Published

1998
1998
2015
2015

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 46 publications
(48 citation statements)
references
References 23 publications
2
46
0
Order By: Relevance
“…1b). These chiral separations were also reported by GC [8,9] but in general very long analysis times were required (more than 1 h). On the other hand, these results do not agree with those obtained by CD-MEKC [13,14], in which g-CD was more effective in the enantiomeric separation of chiral PCBs than b-CD due to the larger size of the cavity of g-CD compared to b-CD.…”
Section: Introductionsupporting
confidence: 68%
See 1 more Smart Citation
“…1b). These chiral separations were also reported by GC [8,9] but in general very long analysis times were required (more than 1 h). On the other hand, these results do not agree with those obtained by CD-MEKC [13,14], in which g-CD was more effective in the enantiomeric separation of chiral PCBs than b-CD due to the larger size of the cavity of g-CD compared to b-CD.…”
Section: Introductionsupporting
confidence: 68%
“…relevance because each enantiomer may have differGas chromatography (GC), usually employed to ent toxicity, activity or metabolic pathways. Moreseparate PCB congeners, has also been employed to perform the separation of chiral PCBs [5][6][7][8][9][10][11]. Nevertheless, the characteristics of capillary electro- and flexibility) make this technique competitive with GC in the field of the enantiomeric separations [12].…”
Section: Introductionmentioning
confidence: 99%
“…[34] Reversal of the elution order of enantiomers has even been observed for apparently identical modified cyclodextrin chiral stationary phases. [35] Therefore, in the present work, we have exercised great care to synthesize, coat, and immobilize the three positional O-2-, O-3-, and O-6-Chirasil-Dex regioisomers onto fused silica capillaries under identical conditions. We demonstrate that the differences in enantioselective chromatographic behaviour are neither pronounced nor negligible.…”
Section: Introductionmentioning
confidence: 99%
“…Because of the different behavior of enantiomers in a chiral environment, enantioselective analysis currently plays an important role in environmental chemistry [4J. First reports of the separation of CTT enantiomers were published in 1994 [5,6]; so far resolution of the enantiomers of CTTs has been achieved on tert-butyldimethylsilylated 13-cyclodextrin (13-BSCD) only [4,7]. Chiral stationary phases (CSPs) based on ~-BSCD were introduced by Blum and Aichholz [8].…”
mentioning
confidence: 99%
“…Chiral stationary phases (CSPs) based on ~-BSCD were introduced by Blum and Aichholz [8]. On this CSP enantioseparation of seven persistent CTTs was achieved in one GC run [7]. The enantiomers of some CTTs could not, however, be separated on 13-BSCD and the lack of a confirmatory CSP for the enantioselective analysis of CTTs in environmental samples was regrettable.…”
mentioning
confidence: 99%