2005
DOI: 10.1002/jssc.200500100
|View full text |Cite
|
Sign up to set email alerts
|

Enantioseparation of baclofen with highly sulfated β‐cyclodextrin by capillary electrophoresis with laser‐induced fluorescence detection

Abstract: Enantioseparation of baclofen with highly sulfated b-cyclodextrin by capillary electrophoresis with laser-induced fluorescence detectionThe enantioseparation of baclofen (4-amino-3-p-chlorophenylbutyric acid) was achieved by CE-LIF with highly sulfated b-CD (HS-b-CD) as chiral selector. Naphthalene-2,3-dicarboxaldehyde was used for the derivatization of nonfluorescent baclofen. HS-b-CD (2%) containing 50 mM borate buffer at pH 9.5 was chosen as the optimal running electrolyte and applied to the analysis of bac… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
19
0

Year Published

2007
2007
2012
2012

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(19 citation statements)
references
References 45 publications
0
19
0
Order By: Relevance
“…Since only a few chiral compounds possess native fluorescence, derivatization procedures are usually required to detect other nonfluorescent analytes. LIF was used for the chiral determination of photosensitizers [32], drugs in human plasma [33], and anticancer agents in drugs [34] achieving LODs around 10 28 M. However, the main application of this detection system in CE was the analysis of amino acid enantiomers in standards [35], foods [36], and biological samples [28,[37][38][39][40][41][42]. In all cases, the methods involved precapillary chiral derivatization of the amino acids with different derivatizing reagents, FITC [35,36], 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) [37], CBI [28,[38][39][40][41], or fluorescamin (FA) [42].…”
Section: On-column Detection In Chiral Analysis By Cementioning
confidence: 99%
“…Since only a few chiral compounds possess native fluorescence, derivatization procedures are usually required to detect other nonfluorescent analytes. LIF was used for the chiral determination of photosensitizers [32], drugs in human plasma [33], and anticancer agents in drugs [34] achieving LODs around 10 28 M. However, the main application of this detection system in CE was the analysis of amino acid enantiomers in standards [35], foods [36], and biological samples [28,[37][38][39][40][41][42]. In all cases, the methods involved precapillary chiral derivatization of the amino acids with different derivatizing reagents, FITC [35,36], 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) [37], CBI [28,[38][39][40][41], or fluorescamin (FA) [42].…”
Section: On-column Detection In Chiral Analysis By Cementioning
confidence: 99%
“…The linearity of calibration curves (R 2 ≥ 0.998) for R-(−) and S-(+)-baclofen was in the concentration range 0.1-2.0 µM. After a simple acetonitrile protein precipitation, the LOD of baclofen in plasma sample was found to be as low as 50 nM (Kavran-Belin et al, 2005).…”
Section: Biogenic Amines Drugs and Catecholsmentioning
confidence: 96%
“…Ionic character of these CD derivatives is responsible for their excellent water solubility. Enhanced enantiomeric recognition as well as solubility of these CDs and their complexes in comparison with their native forms was illustrated on many biological samples (urine, squirrel brain, human plasma), including carboxyethyl-b-CD versus H 1 -antihistaminic drugs (dioxopromethazine, dimethindene, pheniramine) [49,50,121], a highly sulfated-b-CD versus CBI derivatives of serine, glutamate, and aspartate [122], a highly sulfated-b-CD versus CBIderivatized baclofen [73], a highly sulfated-b-CD versus a racemic antiarrhythmic drug (disopyramide) [74], for details see Table 1.…”
Section: Chiral Selectors As Complexing Agents: Advantages and Limitmentioning
confidence: 98%
“…Naphthalene-2,3-dicarboxaldehyde (NDA) derivatized baclofen was separated in human plasma using CD-EKC-LIF method based on a highly sulfated-b-CD [73]. The anionic CD migrated in the opposite direction toward negatively charged baclofen (pH 9.5) transported by EOF toward the cathode.…”
Section: Countercurrent Migrationmentioning
confidence: 99%