1990
DOI: 10.1016/0042-6989(90)90017-f
|View full text |Cite
|
Sign up to set email alerts
|

Equivalent intrinsic blur in amblyopia

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
10
0
2

Year Published

1995
1995
2017
2017

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 43 publications
(13 citation statements)
references
References 43 publications
1
10
0
2
Order By: Relevance
“…As in Figure 2, the corresponding Snellen equivalents are shown on the right y-axis for reference. Log MAR 0 (estimated VA for the unblurred stimulus) increased systematically with log σ int (equivalent intrinsic blur), as has been reported previously for two-line resolution,3,4 and there was a statistically significant correlation between the two parameters ( r = 0.95, p < 0.01). The data were fit with a line with unit slope, which corresponds to the slope of the linear function used previously to describe the relationship between two-line resolution and equivalent intrinsic blur 3,4…”
Section: Resultssupporting
confidence: 86%
See 1 more Smart Citation
“…As in Figure 2, the corresponding Snellen equivalents are shown on the right y-axis for reference. Log MAR 0 (estimated VA for the unblurred stimulus) increased systematically with log σ int (equivalent intrinsic blur), as has been reported previously for two-line resolution,3,4 and there was a statistically significant correlation between the two parameters ( r = 0.95, p < 0.01). The data were fit with a line with unit slope, which corresponds to the slope of the linear function used previously to describe the relationship between two-line resolution and equivalent intrinsic blur 3,4…”
Section: Resultssupporting
confidence: 86%
“…However, when σ stim greatly exceeds σ int , VA is proportional to stimulus blur. Using the equivalent intrinsic blur paradigm, it has been shown previously that normal variation in Vernier acuity,2 two-line resolution thresholds,3,4 and Landolt C acuity6 is related to equivalent intrinsic blur.…”
mentioning
confidence: 98%
“…This function is actually a form of the more familiar function that has been frequently used to quantify equivalent intrinsic noise (Barlow, 1962; Pelli, 1990), i.e., the amount of noise that must be added to a stimulus to elevate thresholds by √2. Levi & Klein (1990) used this parameterization, to quantify the amount of intrinsic blur in amblyopia, i.e., the amount of blur that had to be added to the stimulus to elevate thresholds by √2. This is effectively a measure of the amount of blur (or noise) one can tolerate before performance is degraded.…”
Section: Discussionmentioning
confidence: 99%
“…Jarak ini ditentukan melalui plot keluk Gaussian pada data ketepatan respons. Nisbah jarak kesesakan mendatar-menegak ditunjukkan dalam ruang paling kanan Keputusan kajian ini mencadangkan bahawa kemerosotan penglihatan fovea subjek ambliopia anisometropik berlaku akibat peningkatan kabur intrinsik (Levi & Klein 1990) berbanding subjek normal. Oleh itu, penggunaan kabur ke atas subjek normal, sama ada dengan menggunakan kabur optik atau kabur penuras digital Gaussian, boleh digunakan sebagai model penglihatan fovea ambliopia anisometropik.…”
Section: Uji Kaji 2: Akuiti Periferi Subjek Normal Yang Dikaburkan Peunclassified
“…Pesakit ambliopia anisometropik dilaporkan memiliki kabur intrinsik yang lebih besar daripada individu normal (Levi & Klein 1990). Kabur intrinsik adalah jumlah kabur yang apabila digabungkan dengan kabur rangsangan akan menghasilkan kabur efektif rangsangan tersebut.…”
unclassified