2021
DOI: 10.1186/s12938-021-00942-z
|View full text |Cite
|
Sign up to set email alerts
|

Estimating the accumulative dose uncertainty for intracavitary and interstitial brachytherapy

Abstract: Background Image-guided adaptive brachytherapy shows the ability to deliver high doses to tumors while sparing normal tissues. However, interfraction dose delivery introduces uncertainties to high dose estimation, which relates to normal tissue toxicity. The purpose of this study was to investigate the high-dose regions of two applicator approaches in brachytherapy. Method For 32 cervical cancer patients, the CT images from each fraction were wrapp… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 29 publications
0
2
0
Order By: Relevance
“…Due to the technical characteristics and factors such as less fractions of BT for UCC, online ART had been successfully applied in the BT stage of UCC. In the last two decades, the technique has gradually matured and become routine [ 54 56 ]. Currently, EBRT for UCC is usually performed using coplanar IMRT or VMAT with conventional splitting of dose and 23–28 fractions, which is characterized by multiple fractions and long duration.…”
Section: Discussionmentioning
confidence: 99%
“…Due to the technical characteristics and factors such as less fractions of BT for UCC, online ART had been successfully applied in the BT stage of UCC. In the last two decades, the technique has gradually matured and become routine [ 54 56 ]. Currently, EBRT for UCC is usually performed using coplanar IMRT or VMAT with conventional splitting of dose and 23–28 fractions, which is characterized by multiple fractions and long duration.…”
Section: Discussionmentioning
confidence: 99%
“…This was illustrated by Nix et al (2022) in a series of pelvic patients, where ANACONDA was only used when bladder volume changes were below 80%, pointing out its limitation in handling large deformations. Similarly, Wang et al (2021) acknowledged that ANACONDA struggles to achieve accurate registrations of the upper boundary of the bladder. ANACONDA has also been reported to perform poorly in brachytherapy scenarios characterized by complex deformations due to the applicator insertion (Rigaud et al 2019(Rigaud et al , 2020.…”
Section: Introductionmentioning
confidence: 99%