2012
DOI: 10.1007/s00216-012-6054-z
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of hair roots for detection of methamphetamine and 3,4-methylenedioxymethamphetamine abuse by use of an HPLC–chemiluminescence method

Abstract: We describe the use of hair roots as a matrix for detection of methamphetamine (MP) and 3,4-methylenedioxymethamphetamine (MDMA) abuse. The concentration of drugs was determined in rat hair roots, hair shafts, and plasma after a single administration of MP or MDMA, by use of an HPLC-peroxyoxalate chemiluminescence (PO-CL) method involving column switching. Plasma and hair roots and shafts were collected from male Wistar rats before and after administration of MP (10 mg kg(-1), i.p.). In addition, the roots and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(2 citation statements)
references
References 15 publications
0
2
0
Order By: Relevance
“…Manymethodshave been introduced todetection and measurement of methamphetamine till now. There are several methods for measurement of methamphetamine concentration in various samples including HPLC using fluorescence detection [16][17][18] , HPLC with chemiluminescence detection 19,20 , gas chromatography-mass spectrometry 21,22 , gas chromatography with nitrogen-phosphorus detectio 23 , colourimetric detection using digital and mobile phone technology 24 , andelectrochemistry techniques such as electrochemiluminescence 25,26 .…”
mentioning
confidence: 99%
“…Manymethodshave been introduced todetection and measurement of methamphetamine till now. There are several methods for measurement of methamphetamine concentration in various samples including HPLC using fluorescence detection [16][17][18] , HPLC with chemiluminescence detection 19,20 , gas chromatography-mass spectrometry 21,22 , gas chromatography with nitrogen-phosphorus detectio 23 , colourimetric detection using digital and mobile phone technology 24 , andelectrochemistry techniques such as electrochemiluminescence 25,26 .…”
mentioning
confidence: 99%
“…[31] Compared to fluorescenced etection, CL detection does not requirep hotoexcitation. Due to the lack of ap hotoexcitation sourcea nd the baseline error associated with it, CL is often much more sensitive at detecting analytes.P O-CL/HPLC has been employed to detect traces of methamphetamine-based compounds in rat hair roots, [32] halofantrine-an anthracenemethanold erivativeu sed to treat malaria-in rat plasma, [33] catecholamines in mice brain samples [34] and human plasma [35] amongst many other applications.…”
Section: Po-cl and Chromatographymentioning
confidence: 99%