2003
DOI: 10.1016/s0021-9673(03)01237-8
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of modulators and electron-capture detectors for comprehensive two-dimensional GC of halogenated organic compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
18
0
6

Year Published

2006
2006
2019
2019

Publication Types

Select...
5
4
1

Relationship

0
10

Authors

Journals

citations
Cited by 62 publications
(24 citation statements)
references
References 27 publications
0
18
0
6
Order By: Relevance
“…The main concern in the use of the ECD for GC Â GC has been related to a rather high internal volume. Kristenson et al (2003) evaluated and compared the performance of six modulator types (sweeper, LMCS, quad-jet, dual-jet CO 2 , semirotating cryo, loop) coupled with three commercially available ECDs. The detectors were characterized by different internal volumes, namely 150, 450, and 1500 mL.…”
Section: Instrumentation and Fundamental Operational Parameters 415mentioning
confidence: 99%
“…The main concern in the use of the ECD for GC Â GC has been related to a rather high internal volume. Kristenson et al (2003) evaluated and compared the performance of six modulator types (sweeper, LMCS, quad-jet, dual-jet CO 2 , semirotating cryo, loop) coupled with three commercially available ECDs. The detectors were characterized by different internal volumes, namely 150, 450, and 1500 mL.…”
Section: Instrumentation and Fundamental Operational Parameters 415mentioning
confidence: 99%
“…De acordo com Kristenson e colaboradores, 29 quanto maior o fluxo do gás de make up na determinação de compostos por GCxGC/mECD, menor é o efeito de cauda observado nos picos cromatográficos. Contudo, o efeito de diluição dos compostos no detector é maior.…”
Section: Cromatografia Gasosa Bidimensional Abrangente (Gc×gc)unclassified
“…O uso de detectores por captura de elétrons (ECD, Electron Capture Detector) exige otimização mais cuidadosa de parâmetros operacionais, já que os volumes internos comparativamente grandes dos ECD (150 µL ou mais) tendem a resultar em respostas mais lentas e maior dispersão das bandas cromatográficas. 27 Já a detecção por MS, que está plenamente sedimentada para 1D GC, tem sido bastante discutida visto que seu uso para GC x GC não é trivial. 28 Em primeiro lugar, deve-se considerar que os diagramas gerados são na verdade estruturas de dados em quatro dimensões -Sinal × (m/z) × 1 t R × 2 t R (m/z = relação massa/carga do fragmento iônico).…”
Section: Instrumentação Para Gc × Gcunclassified