2012
DOI: 10.1097/pat.0b013e328359d565
|View full text |Cite
|
Sign up to set email alerts
|

Evaluation of (SD) MPT64 antigen rapid test, for fast and accurate identification of Mycobacterium tuberculosis complex

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 4 publications
0
5
0
Order By: Relevance
“…Of 27 studies, 12 studies used biochemistry method, 13,15,17-e19,25,27e29,31e33 8 used molecular method5,7e9,14,16,22,24 and 7 used biochemistry method plus molecular method as reference test. 20,21,23,26,30,34 Subgroup analysis by reference test showed that pooled sensitivity and specificity for biochemistry method, molecular method and biochemistry method plus molecular method were 94% (CI 93e95%) and 97% (CI 96e99%), 98% (CI 98e99%) and 99% (CI 98e99%), 99% (CI 98e99%) and 98% (CI 96e99%) respectively. There was also considerable heterogeneity (I 2 > 50%) for all the statistical measures.…”
Section: Subgroup Analysismentioning
confidence: 98%
“…Of 27 studies, 12 studies used biochemistry method, 13,15,17-e19,25,27e29,31e33 8 used molecular method5,7e9,14,16,22,24 and 7 used biochemistry method plus molecular method as reference test. 20,21,23,26,30,34 Subgroup analysis by reference test showed that pooled sensitivity and specificity for biochemistry method, molecular method and biochemistry method plus molecular method were 94% (CI 93e95%) and 97% (CI 96e99%), 98% (CI 98e99%) and 99% (CI 98e99%), 99% (CI 98e99%) and 98% (CI 96e99%) respectively. There was also considerable heterogeneity (I 2 > 50%) for all the statistical measures.…”
Section: Subgroup Analysismentioning
confidence: 98%
“…Detection of MPT64 and antigen 85B via immunostaining of tissues and fine-needle aspirates can be rapid and sensitive methods for establishing an early and specific diagnosis of TB infection but are limited to pathology and microbiology laboratories ( 42 , 43 ). Detection of MPT64 in sputum cultures utilizing an immune-chromatographic assay, in conjunction with cording in a stained smear, has been used to make a preliminary yet high-confidence identification of M. tuberculosis complex in liquid culture ( 44 , 45 ). Thus, localization of infection and the low bacterial burden in TB disease usually restricts the specimen type for direct detection methods to sputum or invasively acquired tissues.…”
Section: Discussionmentioning
confidence: 99%
“…Cultures were considered positive only after detection of MTBC by the immunochromatographic assay, SD BIOLINE TB Ag MPT64 (Standard Diagnostics, Seoul, South Korea). This assay is rapid, simple, and reliable with a demonstrated high sensitivity and specific on clinical isolates [ 10 , 11 ].…”
Section: Methodsmentioning