1990
DOI: 10.1016/s0003-2670(00)83545-x
|View full text |Cite
|
Sign up to set email alerts
|

Exchangeable immobilized enzyme reactor for enzyme inhibition tests in flow-injection analysis using a magnetic device. Determination of pesticides in drinking water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
20
0

Year Published

1991
1991
2011
2011

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 82 publications
(20 citation statements)
references
References 10 publications
0
20
0
Order By: Relevance
“…Numerous prototypes based on potentiometric [13,14], amperometric [15][16][17] and piezoelectric [18,19] transducers have been developed. Because the enzymatic activity in AChE-based biosensors is destroyed upon calibration or in the presence of the analyte, the sensor must be discarded after determination [20,21], or, alternatively, the enzyme must be replaced [22][23][24][25] or reactivated [26,27].…”
Section: Introductionmentioning
confidence: 99%
“…Numerous prototypes based on potentiometric [13,14], amperometric [15][16][17] and piezoelectric [18,19] transducers have been developed. Because the enzymatic activity in AChE-based biosensors is destroyed upon calibration or in the presence of the analyte, the sensor must be discarded after determination [20,21], or, alternatively, the enzyme must be replaced [22][23][24][25] or reactivated [26,27].…”
Section: Introductionmentioning
confidence: 99%
“…Some of the reports on immobilized AChE-based single enzyme system apply voltages of + 400 to + 700 mV for the oxidation of thiocholine. [7][8][9][10] AChE can be immobilized on electrode surface by using a variety of matrices such as cross-linked polymers, [11] crosslinked bovine serum albumin, [12,13] chitosan [2] and cellulose, [14] different support matrices such as nylon, [5,12,15] controlled pore glass, [16] magnetic particles, [10,17] or the strong affinity linking with concanavalin A [18] and metal ions. [19] To reduce the working potential mediators such as 7,7,8,8-tetracyanoquinodimethane (TCNQ) [19][20][21][22] have been deposited on surface to shuttle electrons between the thiocholine formed and the electrode.…”
Section: Introductionmentioning
confidence: 99%
“…Finally, the background fluid is eluted by a buffer in a washing step, leaving behind the magnetically immobilized particle-target conjugate. 6 In contrast to its batch counterpart, a͒ Author to whom correspondence should be addressed. Electronic mail: ikpuri@vt.edu.…”
Section: Introductionmentioning
confidence: 99%