1999
DOI: 10.1109/63.761699
|View full text |Cite
|
Sign up to set email alerts
|

Experimental comparison of motor bearing currents with PWM hard- and soft-switched voltage-source inverters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
3
0
2

Year Published

2000
2000
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 49 publications
(7 citation statements)
references
References 16 publications
2
3
0
2
Order By: Relevance
“…This is in accordance with the above-noted theory that EDM-currents are not related to the stator ground current [11]. For example, the stator ground current is only 50% in configuration E3 when compared to E1.…”
Section: Influence Of Grounding Configurationsupporting
confidence: 90%
See 1 more Smart Citation
“…This is in accordance with the above-noted theory that EDM-currents are not related to the stator ground current [11]. For example, the stator ground current is only 50% in configuration E3 when compared to E1.…”
Section: Influence Of Grounding Configurationsupporting
confidence: 90%
“…However, the EDM-currents in configuration E1 and E3 are nearly the same. Again, in accordance with the above-noted theory [10,11], the picture is different for the circular bearing currents of the 110 kW power level. A reduction of the stator ground currents in configuration E2, when compared with configuration E1, also yields a reduction of bearing currents by 50%.…”
Section: Influence Of Grounding Configurationsupporting
confidence: 86%
“…This accumulated rotor charge eventually discharges through the bearings if no other galvanic current path is provided. Over time, these discharges can cause serious pitting of the bearing balls and races that eventually leads to bearing failures under some circumstances that have been experienced in field installa- tions [20]- [25]. The introduction of insulated bearings or grounded rotor shaft brushes are among the solutions adopted by machine manufacturers to prevent these bearing failures.…”
Section: ) Inverter Stagementioning
confidence: 99%
“…It is termed "non-circulating" because these currents pass through the bearings unidirectionally from the rotor to the stator [60]. The dv/dt related currents can be conductive and capacitive [62]. The conductive currents mainly occur when the motor is running at a low speed.…”
Section: "Non-circulating" Currentsmentioning
confidence: 99%