2022
DOI: 10.1155/2022/5466268
|View full text |Cite
|
Sign up to set email alerts
|

Experimental Harmonics Analysis of UPS (Uninterrupted Power Supply) System and Mitigation Using Single-Phase Half-Bridge HAPF (Hybrid Active Power Filter) Based on Novel Fuzzy Logic Current Controller (FLCC) for Reference Current Extraction (RCE)

Abstract: UPS Uninterruptible power supply) is used as backup when the input source, usually the national grid, fails to give power to a load. In addition to the growing use of electronic power devices in industrial and residential systems, such as UPS, controlled rectifiers, SMPS (Switch Mode Power Supplies), and DC Converters, there is a serious problem caused by harmonics in AC mains, which lowers the power quality. Harmonics can cause a variety of problems, including sensitive equipment failure, resonance issues, he… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3
1
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 43 publications
0
3
0
Order By: Relevance
“…The reverse current produced by the inverter is introduced into the system to compensate for the harmonic currents; these currents are obtained using the p-q theory. To achieve neutral current compensation, two main topologies are used: (i) inverters to generate voltages; (ii) Inverters with two midpoint capacitors and a four-arm inverter (used as an active filter) (Barva et al 2018;Kumar et al 2022;Collins et al 2022;Zhang et al 2022;Challa et al 2022). Mainly, the four-wire shunt active filters, with three phases, have three branches with two switches controlled by the PWM technique and the fourth leg is on standby and has two switches controlled by the PWM technique.…”
Section: Description and Modeling Of The Studied Microgrid Systemmentioning
confidence: 99%
“…The reverse current produced by the inverter is introduced into the system to compensate for the harmonic currents; these currents are obtained using the p-q theory. To achieve neutral current compensation, two main topologies are used: (i) inverters to generate voltages; (ii) Inverters with two midpoint capacitors and a four-arm inverter (used as an active filter) (Barva et al 2018;Kumar et al 2022;Collins et al 2022;Zhang et al 2022;Challa et al 2022). Mainly, the four-wire shunt active filters, with three phases, have three branches with two switches controlled by the PWM technique and the fourth leg is on standby and has two switches controlled by the PWM technique.…”
Section: Description and Modeling Of The Studied Microgrid Systemmentioning
confidence: 99%
“…The main problems of thyristors based AC-DC converts are the issue of harmonics and low power qualities [5]. The setback associated with harmonics and low power factor are minimized by increasing the number of pulses (multiphase AC-DC converters such as 6-pulse, 12-pulse, 18-pulse, 24-pulse, 36-pulse, 48-pulse) [6][7] and applications of filter components (both active and passive types) and they have been addressed and published online by many authors [8][9][10].…”
Section: Introductionmentioning
confidence: 99%
“…The suggested adaptive-HSAPF is monitored using MATLAB/Simulink and real-time scenarios under steady-state and transient conditions. A fuzzy logic controller is applied for a single-phase half-bridge for PWM generation [31]. The performance is tested in transient and steady-state conditions.…”
Section: Introductionmentioning
confidence: 99%