2013
DOI: 10.1016/j.microc.2012.12.005
|View full text |Cite
|
Sign up to set email alerts
|

Extraction and detection of organoarsenic feed additives and common arsenic species in environmental matrices by HPLC–ICP-MS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
43
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 97 publications
(45 citation statements)
references
References 49 publications
2
43
0
Order By: Relevance
“…The quantitative and reproducible extraction of arsenic species was considered as the most challenging aspect in the speciation analysis of organoarsenicals relevant to chicken feed [47]. Both organic and inorganic arsenic species are expected to be present in chicken.…”
Section: Introductionmentioning
confidence: 99%
“…The quantitative and reproducible extraction of arsenic species was considered as the most challenging aspect in the speciation analysis of organoarsenicals relevant to chicken feed [47]. Both organic and inorganic arsenic species are expected to be present in chicken.…”
Section: Introductionmentioning
confidence: 99%
“…Quantitative analysis of arsenic species was conducted on a 7700x Inductively Coupled Plasma Mass Spectrometer (ICP-MS) hyphenated with a 1200 High Performance Liquid Chromatograph (HPLC) (Agilent, Santa Clara, USA) (Liu et al, 2013). As(III), As(V), and p-ASA (injection volume: 20 mL) were separated on a PRP-X100 anion exchange chromatographic column (5 mm, 4.6 Â 250 mm) (Hamilton, Reno, USA) by isocratic elution with 20% H 2 O and 80% 50 mmol L À1 (NH 4 ) 2 HPO 4 (pH ¼ 5.4, acidified by 0.3% nitric acid) at 1.5 mL min…”
Section: Methodsmentioning
confidence: 99%
“…The details of the instrumentation and elimination of analysis interferences can be found in our previous studies [23,24]. The sample injection volume was 40 L in HPLC-ICP-MS analysis.…”
Section: Arsenic Speciation Analysismentioning
confidence: 99%
“…The sample injection volume was 40 L in HPLC-ICP-MS analysis. The inorganic and organic arsenic species were separated on a Hamilton PRP-X100 anion exchange chromatographic column (4.6 × 250 mm, 5 m) with gradient elution, following the method reported previously [23]. In brief, two mobile phases with a combined flow rate of 1 mL/min were used for separation of the arsenic species: (A) triple-distilled water, and (B) a buffer solution of 50 mmol/L (NH 4 ) 2 HPO 4 with 0.1% v/v TFA and 0.2% v/v HNO 3 at pH 6.0 (adjusted by dilute ammonium hydroxide solution).…”
Section: Arsenic Speciation Analysismentioning
confidence: 99%
See 1 more Smart Citation