2015
DOI: 10.1116/1.4930040
|View full text |Cite
|
Sign up to set email alerts
|

Fabrication and comparison of MoS2 and WSe2 field-effect transistor biosensors

Abstract: The authors present a study on the evolution behaviors of the transfer characteristics of MoS2 and WSe2 field-effect transistor biosensors when they are subjected to tumor necrosis factor-alpha and streptavidin solutions with varying analyte concentrations. Both MoS2 and WSe2 sensors exhibit very low detection limits (∼60 fM for tumor necrosis factor-alpha detection; ∼70 fM for streptavidin detection). However, WSe2 sensors exhibit the higher linear-regime sensitivities in comparison with MoS2 sensors. In part… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
47
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 42 publications
(48 citation statements)
references
References 23 publications
1
47
0
Order By: Relevance
“…the photoluminescence spectra (PL) of MoS 2 reveals the possibility of optical biosensors 19 ; modulation in PL due to the presence of DNA base could serve as a fingerprint for selective optical biosensing 19 ; nano-pore in pristine MoS 2 results in fast detection of DNA bases 17 ; MoS 2 based biomedical sensor shows promise to detect DNA origami, tumor necrosis factor-alpha (TNF-a) molecules etc. [21][22][23][24][25] .…”
Section: Introductionmentioning
confidence: 98%
“…the photoluminescence spectra (PL) of MoS 2 reveals the possibility of optical biosensors 19 ; modulation in PL due to the presence of DNA base could serve as a fingerprint for selective optical biosensing 19 ; nano-pore in pristine MoS 2 results in fast detection of DNA bases 17 ; MoS 2 based biomedical sensor shows promise to detect DNA origami, tumor necrosis factor-alpha (TNF-a) molecules etc. [21][22][23][24][25] .…”
Section: Introductionmentioning
confidence: 98%
“…Measurements in this region of operation have been reported which show detection of streptavidin at the oxide-APTES-biotin interface. 25,35,44,49,120 Data from these publications is tabulated in ESI sections 5 and 9. † Three publications contained data with response as a function of streptavidin concentration, giving a Sensitivity of 72%, 162 63% 120 and 0.5%.…”
Section: Streptavidin Sensing Datamentioning
confidence: 99%
“…26,28,32,36,49,51,107,120,[160][161][162][163][164][165][166] The simplest model for biomolecule-binding reactions, is the first-order Langmuir model of surface-reactions (details in ESI section 10 †). In this model the surface reaction of analyte (A) to the surface sites (S) is treated simply:…”
Section: Surface Binding Reactionsmentioning
confidence: 99%
“…, MoS 2 ) may exhibit better performance than graphene for this application. 5,6 However, reproducible, high-yield fabrication processes are necessary for this emerging technology.…”
mentioning
confidence: 99%