Factors influencing trace ion analysis with preconcentration by electrostacking

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
25
0

Year Published

1997
1997
2008
2008

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 42 publications
(25 citation statements)
references
References 14 publications
0
25
0
Order By: Relevance
“…The electromigration dispersion predicted in a CuSO 4 system has been confirmed experimentally [4,35]. The reversed elution order of Na 1 and Ca 2+ has been observed which is caused by complexation of Ca 2+ ions with sulfate anions [4,35]. The presence , poly(diallyldimethylammonium) hydroxide; Bis-Tris, bis(2-hydroxyethyl)imino-tris(hydroxymethyl)methane; SAE, strong anion exchanger; SCX, strong cation exchanger …”
Section: Prediction Of Ce Separationsmentioning
confidence: 73%
“…The electromigration dispersion predicted in a CuSO 4 system has been confirmed experimentally [4,35]. The reversed elution order of Na 1 and Ca 2+ has been observed which is caused by complexation of Ca 2+ ions with sulfate anions [4,35]. The presence , poly(diallyldimethylammonium) hydroxide; Bis-Tris, bis(2-hydroxyethyl)imino-tris(hydroxymethyl)methane; SAE, strong anion exchanger; SCX, strong cation exchanger …”
Section: Prediction Of Ce Separationsmentioning
confidence: 73%
“…Taking these results into account, a detection limit (LOD) of approximately 1 ng mL -1 should be attainable. This LOD can be achieved by transient isotachophoretic preconcentration during the electrokinetic sample introduction [10,13]. The disadvantage of the method described is in the use of octanesulfonate, because this cannot be obtained without sulfate contamination.…”
Section: Optimization By Taguchi's Experimental Designmentioning
confidence: 98%
“…For this purpose the wafer surface is completely wetted with a minimum volume of ultrapure water (UPW) necessary to obtain a suitable sample volume. The ultra trace methods described in the literature [9][10][11][12][13] have the disadvantage that octanesulfonate is used for transient isotachophoretic preconcentration during the electrokinetic sample introduction. Octanesulfonate, however, cannot be obtained without sulfate contamination.…”
Section: Introductionmentioning
confidence: 99%
“…Since these methods were obviously time-consuming and tedious, on-column sample stacking methods have been developed for coupling with CE. As reported in some references, the on-column sample stacking methods such as pH-mediated sample stacking [15], on-column isotachophoresis [16,17], field-amplified [18], large-volume sample stacking [19] and electrostacking [20], have been applied to pre-concentrate the polar analytes which can be loaded into the capillary and improve the analytical sensitivity.…”
mentioning
confidence: 99%