2009
DOI: 10.1007/s10967-009-0242-0
|View full text |Cite
|
Sign up to set email alerts
|

Fast method of XANES data collection suitable for oxidation state mapping

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2010
2010
2020
2020

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 11 publications
0
7
0
Order By: Relevance
“…The authors finally minimized the beam damage by keeping the specimen at the temperature of liquid nitrogen (‐178 °C) during data collection. Bielewski et al suggested that long‐time exposure of actinides to SR would result in transformations of the oxidation state, and a fast method for XANES data collection would be more suitable for oxidation state mapping. Actually, radiation effects on actinide oxides and complexes by subjecting samples to a self‐irradiation field or an external radiation field of α, β or γ rays were well studied in the last decades.…”
Section: Resultsmentioning
confidence: 99%
“…The authors finally minimized the beam damage by keeping the specimen at the temperature of liquid nitrogen (‐178 °C) during data collection. Bielewski et al suggested that long‐time exposure of actinides to SR would result in transformations of the oxidation state, and a fast method for XANES data collection would be more suitable for oxidation state mapping. Actually, radiation effects on actinide oxides and complexes by subjecting samples to a self‐irradiation field or an external radiation field of α, β or γ rays were well studied in the last decades.…”
Section: Resultsmentioning
confidence: 99%
“…These effects are also considered in fundamental parameter models for quantitative XRF analysis. Bielewski et al 487 reported a fast XANES data collection method suitable for mapping oxidation states of actinides in environmental samples. This is a welcome improvement since the time required for conventional XANES data collection is unacceptably long.…”
Section: Chemical State and Speciationmentioning
confidence: 99%
“…Neither the normalized white line intensities nor the peak widths changed with repeated scans of the same 0.1 μm 2 area, but the normalized peak intensity did vary by approximately 10–20% between deposits (Figures 5a, 5b, and 5c), with more concentrated spots, for example spot A in Figure 5, typically giving less intense white lines than spots with less plutonium. The favorable counting statistics in the more concentrated Pu spots also makes rapid mapping of the Pu oxidation state feasible [16]. …”
Section: Resultsmentioning
confidence: 99%
“…A few X-ray microprobe studies of the elemental distribution and speciation of transuranic elements have been reported, but these studies have been principally conducted on inorganic samples with X-ray beams focused to 10 – 200 μm 2 spots [916]. In this work we report details of submicron (0.1 μm 2 ) hard X-ray SXFM studies of the accumulation and distribution of the transuranic element plutonium in a complex matrix, living cells.…”
Section: Introductionmentioning
confidence: 99%