2019
DOI: 10.1016/j.mvr.2019.02.005
|View full text |Cite
|
Sign up to set email alerts
|

Flow Mediated Skin Fluorescence technique reveals remarkable effect of age on microcirculation and metabolic regulation in type 1 diabetes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
29
0

Year Published

2019
2019
2025
2025

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 29 publications
(29 citation statements)
references
References 20 publications
0
29
0
Order By: Relevance
“…FMSF measures changes in NADH fluorescence intensity as a response to blocking and releasing blood flow in the forearm, as a function of time. The FMSF technique has been successfully applied for non-invasive diagnostics and monitoring of the microcirculation, metabolic regulation, and vascular complications in diabetes patients (Katarzynska et al, 2019b(Katarzynska et al, , 2020a. Very recently, the FMSF technique was used to monitor microcirculatory oscillations known as flowmotion (Katarzynska et al, 2020b).…”
Section: Contents Lists Available At Sciencedirectmentioning
confidence: 99%
“…FMSF measures changes in NADH fluorescence intensity as a response to blocking and releasing blood flow in the forearm, as a function of time. The FMSF technique has been successfully applied for non-invasive diagnostics and monitoring of the microcirculation, metabolic regulation, and vascular complications in diabetes patients (Katarzynska et al, 2019b(Katarzynska et al, , 2020a. Very recently, the FMSF technique was used to monitor microcirculatory oscillations known as flowmotion (Katarzynska et al, 2020b).…”
Section: Contents Lists Available At Sciencedirectmentioning
confidence: 99%
“…and reaches maximum (FL max) in response to ischemia and the accumulation of NADH in keratinocytes. Results are displayed as ischemic response maximum (IR max) and ischemic response area under the curve (IR auc) [17]. Finally, a reperfusion (hyperaemic) stage takes place following sphygmomanometer release: NADH fluorescence rapidly decreases and reaches minimum (FL min) within the first few seconds of reperfusion and then recovers, less steeply, to the baseline level within 4.5 minutes.…”
Section: Methodsmentioning
confidence: 99%
“…Finally, a reperfusion (hyperaemic) stage takes place following sphygmomanometer release: NADH fluorescence rapidly decreases and reaches minimum (FL min) within the first few seconds of reperfusion and then recovers, less steeply, to the baseline level within 4.5 minutes. Results are displayed as hyperemic response max (HR max) and hyperemic response area under the curve (HR auc) [17]. To illustrate, typical results and definitions of measured parameters, obtained in one individual of the healthy control group, are presented in Figure 1.…”
Section: Methodsmentioning
confidence: 99%
“…[2][3][4][5] Recently, using FMSF, we identified an unexpected effect of age on the vascular circulation and metabolic regulation in patients with type 1 diabetes (DM1). 6 The present contribution briefly describes the diagnostic potential of FMSF in the case of type 2 diabetes (DM2). Special attention is given to the ability of the FMSF technique to predict complications related to cardiovascular disease (CVD) associated with the progress of DM2.…”
mentioning
confidence: 99%
“…2-5 Recently, using FMSF, we identified an unexpected effect of age on the vascular circulation and metabolic regulation in patients with type 1 diabetes (DM1). 6…”
mentioning
confidence: 99%