2022
DOI: 10.1039/d1nj06011b
|View full text |Cite
|
Sign up to set email alerts
|

Fluorimetric and ratiometric colorimetric dual-mode detection of organophosphorus pesticides based on carbon dots/DTNB

Abstract: In this work, a fluorimetric and ratiometric colorimetric dual-mode detection method was developed for organophosphorus pesticides (OPs) based on carbon dots (CDs)/5,5-dithiobis-(2-nitrobenzoic acid) (DTNB). Its main mechanism is that OPs...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(2 citation statements)
references
References 51 publications
0
2
0
Order By: Relevance
“…To verify the accuracy of the proposed method, the detection results of our method for AChE activity determination were compared with the typical colorimetric method (DTNB) for AChE activity (Table S6). The colorimetric principle is based on the hydrolysis of ACh catalyzed by AChE to produce choline, which reacts with 5,5-dithiobis(2-nitrobenzoic acid) (DTNB) to produce 5-thio-2-nitrobenzoic acid (TNB), which has an obvious absorption peak at 420 nm. , The absorbance was recorded to calculate the AChE activity, as shown in Figure S15. The results of the proposed method are consistent with those of the typical colorimetric method, and Figure indicates that there is no significant difference for the found values between the two assay protocols ( P > 0.05).…”
Section: Resultsmentioning
confidence: 99%
“…To verify the accuracy of the proposed method, the detection results of our method for AChE activity determination were compared with the typical colorimetric method (DTNB) for AChE activity (Table S6). The colorimetric principle is based on the hydrolysis of ACh catalyzed by AChE to produce choline, which reacts with 5,5-dithiobis(2-nitrobenzoic acid) (DTNB) to produce 5-thio-2-nitrobenzoic acid (TNB), which has an obvious absorption peak at 420 nm. , The absorbance was recorded to calculate the AChE activity, as shown in Figure S15. The results of the proposed method are consistent with those of the typical colorimetric method, and Figure indicates that there is no significant difference for the found values between the two assay protocols ( P > 0.05).…”
Section: Resultsmentioning
confidence: 99%
“…Carbon dots with 5,5-dithiobis-(2-nitrobenzoic acid) were used for fluorometric and colorimetric dual detection method for detecting organophosphorus pesticides. The method was highly sensitive, selective and accurate [41].…”
Section: Applications Of Cnds In Detection Of Poisonsmentioning
confidence: 96%