Fundamental limit of detection of photonic biosensors with coherent phase read-out

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
25
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2
1

Relationship

3
5

Authors

Journals

citations
Cited by 41 publications
(27 citation statements)
references
References 37 publications
2
25
0
Order By: Relevance
“…In the past year, Optics Express has published some articles dealing with state-of-the-art Mach-Zehnder interferometers and their improvements. Learning from telecommunications, a coherent phase readout by directional coupler and differential detector detection [316], an optimizing optical attenuation with varying electrical power in the thermos-optic phase shifter on the reference arm of the Mach-Zehnder chip [317] or finally implementing an electro-optic comb sensor with some electronics for the phase modulation [318] were fabricated.…”
Section: Dual Pathwaymentioning
confidence: 99%
“…In the past year, Optics Express has published some articles dealing with state-of-the-art Mach-Zehnder interferometers and their improvements. Learning from telecommunications, a coherent phase readout by directional coupler and differential detector detection [316], an optimizing optical attenuation with varying electrical power in the thermos-optic phase shifter on the reference arm of the Mach-Zehnder chip [317] or finally implementing an electro-optic comb sensor with some electronics for the phase modulation [318] were fabricated.…”
Section: Dual Pathwaymentioning
confidence: 99%
“…Using the additional degree of freedom afforded by a shift, ξ, between the loading segments this approach has enabled the demonstration of filter bandwidths as narrow as 200pm with 30dB extinction [11]. The enhanced modal interaction can also be exploited to improve the sensitivity of photonic biosensors [12], which through careful design of the complete sensing system will result in better detection limits [13].…”
Section: High Performance Subwavelength Devicesmentioning
confidence: 99%
“…We have analytically studied the impact of these factors on the LOD, arring at a closed form expression. This expression is valid for both interferometric and ring resonators with coherent detection scheme and holds for interferometric architectures with conventional read-out, at the quadrature point, too, thereby enabling us to formulate clear guidelines for sensor optimization [5]. Fig.…”
mentioning
confidence: 90%
“…1(b The LOD is the smallest change in analyte that can be detected by the biosensing system. In addition to its dependency on the waveguide sensitivity, it is critically limited by the signal attenuation and noise [5]. We have analytically studied the impact of these factors on the LOD, arring at a closed form expression.…”
mentioning
confidence: 99%