1993
DOI: 10.1016/0165-1838(93)90051-u
|View full text |Cite
|
Sign up to set email alerts
|

Fundamental patterns and characteristics of the laser-doppler skin blood flow waves recorded from the finger or toe

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
22
0

Year Published

1994
1994
2015
2015

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 38 publications
(24 citation statements)
references
References 14 publications
2
22
0
Order By: Relevance
“…In the periphery, vessel diameter changes or vasomotion have been investigated with plethysmograph devices, 27,28 and Mayer waves have been shown in a study comparing the finger, toe, and arm as measurement sites using laser Doppler in healthy participants. 25 More interestingly, results of the latter study also demonstrated temporal synchrony between the different peripheral measurement sites in the low-frequency domain. 25 Considering that modulations in oxygen consumption, measurable with NIRS in various peripheral sites, have been investigated for the purposes of following disease progression or aging-related processes, 21 further characterization of these peripheral signals seems valuable.…”
Section: Introductionmentioning
confidence: 49%
See 2 more Smart Citations
“…In the periphery, vessel diameter changes or vasomotion have been investigated with plethysmograph devices, 27,28 and Mayer waves have been shown in a study comparing the finger, toe, and arm as measurement sites using laser Doppler in healthy participants. 25 More interestingly, results of the latter study also demonstrated temporal synchrony between the different peripheral measurement sites in the low-frequency domain. 25 Considering that modulations in oxygen consumption, measurable with NIRS in various peripheral sites, have been investigated for the purposes of following disease progression or aging-related processes, 21 further characterization of these peripheral signals seems valuable.…”
Section: Introductionmentioning
confidence: 49%
“…25 More interestingly, results of the latter study also demonstrated temporal synchrony between the different peripheral measurement sites in the low-frequency domain. 25 Considering that modulations in oxygen consumption, measurable with NIRS in various peripheral sites, have been investigated for the purposes of following disease progression or aging-related processes, 21 further characterization of these peripheral signals seems valuable.…”
Section: Introductionmentioning
confidence: 49%
See 1 more Smart Citation
“…This is the common nature of any tissue perfusion. There is recent evidence that the absence or presence of specific waves in the perfusion signal relates to the influence of a specific disease on the microvascular perfusion [40,41]. The perfusion signal is, however, non-stationary and spectral analysis must be carried out with this in mind.…”
Section: 6mentioning
confidence: 99%
“…[16][17][18][19][20][21][22][23][24][25][26][27][28][29][30][31][32][33][34][35] the TPP value as compared with that of TRR.…”
mentioning
confidence: 99%