2006 IEEE International Frequency Control Symposium and Exposition 2006
DOI: 10.1109/freq.2006.275466
|View full text |Cite
|
Sign up to set email alerts
|

GaPO4 Stiffness and Piezoelectric Constants Measurements using the Combined Thickness Excitation and Lateral Field Technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
17
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 14 publications
(19 citation statements)
references
References 9 publications
2
17
0
Order By: Relevance
“…Since all samples were prepared in the same manner, this seems to be in disagreement with the experiment, where we saw an almost four times smaller coefficient in the GPO structure. A likely explanation for this is the existence of a large discrepancy between the piezoelectric/dielectric coefficients of GPO found in the literature [22,24,35] and the actual properties of the commercial crystals, which are unknown to us.…”
Section: A C C E P T E D Accepted Manuscriptmentioning
confidence: 88%
See 3 more Smart Citations
“…Since all samples were prepared in the same manner, this seems to be in disagreement with the experiment, where we saw an almost four times smaller coefficient in the GPO structure. A likely explanation for this is the existence of a large discrepancy between the piezoelectric/dielectric coefficients of GPO found in the literature [22,24,35] and the actual properties of the commercial crystals, which are unknown to us.…”
Section: A C C E P T E D Accepted Manuscriptmentioning
confidence: 88%
“…Its constitutive elastostatic, electrostatic and magnetostatic equations were then solved assuming averaged homogeneous tensor fields in each perfectly elastically coupled layer (k C = 1) and under unclamped and open circuit boundary conditions. The linear anisotropic electric, magnetic and elastic material constants were obtained from the literature (Metglas [27][28][29], LNO [23], and α-GPO [22,24]). We note that a pseudopiezomagnetic approximation was assumed for the MS layer which is valid in the small region of the magnetostriction curve where the elastic strain (S i ) changes linearly with the applied bias field (H k ), and M A N U S C R I P T A C C E P T E D ACCEPTED MANUSCRIPT 4 the slope ∂S i /∂H k is maximized in such a way that S i = q ki H k where q ki denotes the piezomagnetic coefficient.…”
Section: Preliminary Calculationsmentioning
confidence: 99%
See 2 more Smart Citations
“…The principle function of the transducer is to enable single excitation and reception of waves which can only be achieved if the transducer has an appropriate broadband frequency response. A previous study on different crystal orientation of GaPO4 identified Y-cut to achieve a pure shear mode of vibration [2] and was therefore chosen for this study. To achieve a pure thickness shear mode of vibration and the desired frequency response from the GaPO4 element, its length (13 mm), width (3 mm) and thickness (0.5 mm) was chosen to provide an aspect ratio of 26 (>20 [3]) for this study.…”
Section: Introductionmentioning
confidence: 99%