1988
DOI: 10.1039/an9881300735
|View full text |Cite
|
Sign up to set email alerts
|

Graphite paste-based enzymatic glucose electrode for flow injection analysis

Abstract: The amperometric determination of glucose can b e performed using a flow injection system with a wall-jet flow-through cell and a graphite paste electrode. The working electrode is prepared from a mixture of graphite powder, silicone oil and glucose oxidase and exhibits a linear response in a single-line manifold for glucose concentrations u p to 30 r n M with a sampling rate of 120 s a m p l e s per hour. The detection limit calculated for a 750-p1 s a m p l e volume injected is 20 p~ glucose. The average lif… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
29
0
2

Year Published

1992
1992
2013
2013

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 74 publications
(31 citation statements)
references
References 0 publications
0
29
0
2
Order By: Relevance
“…O primeiro eletrodo de pasta de carbono 8 foi desenvolvido, em 1958, na tentativa de preparar um eletrodo de carbono renovável para ser usado em uma ampla faixa de potenciais positivos onde o eletrodo de mercúrio metálico não é aplicável devido à sua oxidação. No entanto, o primeiro eletrodo de pasta de carbono modificado com enzima (glicose oxidase) foi proposto apenas no final da déca-da de 80 9 , e desde então vários biossensores foram desenvolvidos usando diversos materiais biológicos [10][11][12][13][14][15][16] . A pasta de carbono é uma mistura de pó de grafite e aglutinante.…”
Section: Introductionunclassified
“…O primeiro eletrodo de pasta de carbono 8 foi desenvolvido, em 1958, na tentativa de preparar um eletrodo de carbono renovável para ser usado em uma ampla faixa de potenciais positivos onde o eletrodo de mercúrio metálico não é aplicável devido à sua oxidação. No entanto, o primeiro eletrodo de pasta de carbono modificado com enzima (glicose oxidase) foi proposto apenas no final da déca-da de 80 9 , e desde então vários biossensores foram desenvolvidos usando diversos materiais biológicos [10][11][12][13][14][15][16] . A pasta de carbono é uma mistura de pó de grafite e aglutinante.…”
Section: Introductionunclassified
“…Similarly, covalent binding of the redox mediator via long and flexible spacer chains either to the electrode surface (seaweed mechanism) or to the outer surface of the enzyme itself (whip mechanism), has also been proposed as alternative [12,73]. Mixing the mediator into the carbon paste (graphite powder) is a relatively easy and effective method of mediator integration [74][75][76][77][78][79][80][81]. These carbon pastes can be further modified with stabilizers [82] or polyelectrolytes [75] to increase the long-term stability, response time, etc.…”
Section: Mediated Electron Transfer (Met)mentioning
confidence: 99%
“…Since the first reported work on carbon paste enzyme electrodes (Matuszewski and Trojanowicz, 1988), a type of conductive matrix enzyme electrode, a significant amount of research has been focused on constructing enzyme electrodes by this approach (Gorton, 1995). For example, by immobilizing an oxidoreductase together with an electron transfer mediator on a carbon particle matrix and applying such a mixture onto a conductive electrode, an active membrane is formed where the concentration of a specific chemical reagent can be measured by amperometric means (Rosen-Margalit et al, 1993).…”
Section: Introductionmentioning
confidence: 99%