High sensitive analysis of steroids in doping control using gas chromatography/time‐of‐flight mass‐spectrometry

Abstract: The method of high sensitive gas chromatographic/time-of-flight mass-spectrometric (GC/TOF-MS) analysis of steroids was developed. Low-resolution TOF-MS instrument (with fast spectral acquisition rate) was used. This method is based on the formation of the silyl derivatives of steroids; exchange of the reagent mixture (pyridine and N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA)) for tert-butylmethylether; offline large sample volume injection of this solution based on sorption concentration of the respectiv… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
18
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(18 citation statements)
references
References 7 publications
0
18
0
Order By: Relevance
“…Numerous analytical methods have been developed and applied to steroids analysis using various instrumental set‐ups including chromatography and mass spectrometry. Gas chromatography‐electron ionization/mass spectrometry (GC‐EI/MS) with trimethylsilylation (TMS) derivatives is the traditional technique used to detect anabolic steroids . Recently, gas chromatography‐electron ionization/tandem mass spectrometry (GC‐EI/MS/MS) has been shown to be a powerful analytical method for steroid analysis .…”
Section: Introductionmentioning
confidence: 99%
“…Numerous analytical methods have been developed and applied to steroids analysis using various instrumental set‐ups including chromatography and mass spectrometry. Gas chromatography‐electron ionization/mass spectrometry (GC‐EI/MS) with trimethylsilylation (TMS) derivatives is the traditional technique used to detect anabolic steroids . Recently, gas chromatography‐electron ionization/tandem mass spectrometry (GC‐EI/MS/MS) has been shown to be a powerful analytical method for steroid analysis .…”
Section: Introductionmentioning
confidence: 99%
“…Hence, the development of full acquisition methods based on HR instru ments is a promising alternative, not only for the open detection of AAS but also for the compre hensive target screening in doping control ana lysis (Table 2) [50][51][52][53][54][55][56][57][58][59][60][61][62][63][64][65][66]. Their modus operandi is the acquisition of the fullscan raw data and, therefore, the detection of all compounds ion ized by the source.…”
Section: Neutral Loss Scan Methodsmentioning
confidence: 99%
“…Bioanalytical challenges in the detection of unknown anabolic androgenic steroids | Review www.future-science.com Theoretically application [50] Dilute and shoot Positive samples [59] Dilute and shoot …”
Section: Neutral Loss Scan Methodsmentioning
confidence: 99%
“…The effective screening of anabolic steroids in doping control is critical, as according to the recently published Anti‐Doping Testing Figures Report by WADA, anabolic agents are still the most reported misused prohibited substances amongst all substance groups. The conventional method for the detection of anabolic steroids in biological samples is by the use of gas chromatography‐mass spectrometry (GC‐MS) . Liquid chromatography‐mass spectrometry (LC‐MS) has become a compatible technique for doping control testing in sports in recent years as LC‐MS has the ability to handle heat labile and large biomolecules, with faster instrument turnaround time and better sensitivity .…”
Section: Introductionmentioning
confidence: 99%