IEEE SENSORS 2014 Proceedings 2014
DOI: 10.1109/icsens.2014.6985137
|View full text |Cite
|
Sign up to set email alerts
|

High sensitive detection in tumor extracts with SiNW-FET in-air biosensors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
10
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(11 citation statements)
references
References 11 publications
1
10
0
Order By: Relevance
“…A SiNW-based device was previously reported for the detection of pathogenic factors at very low concentrations (fM) in phosphate buffered saline (PBS). In this device, the SiNW senses rabbit antigen molecules in the presence of a 100 000 mass excess of the non-specific tumor protein, indicating that the biosensor is excessively resistant to noise (Puppo et al, 2014).…”
Section: Protein Sensors Regonda Et Al Demonstrated a New Fet-biosementioning
confidence: 99%
“…A SiNW-based device was previously reported for the detection of pathogenic factors at very low concentrations (fM) in phosphate buffered saline (PBS). In this device, the SiNW senses rabbit antigen molecules in the presence of a 100 000 mass excess of the non-specific tumor protein, indicating that the biosensor is excessively resistant to noise (Puppo et al, 2014).…”
Section: Protein Sensors Regonda Et Al Demonstrated a New Fet-biosementioning
confidence: 99%
“…Although nanowire-based detection of protein cancer markers has clearly evolved from the measurement of purified markers spiked into buffer to the measurement of markers spiked into healthy human serum, a very limited number of studies have quantified these markers in cancer patient blood-derived specimens [27,28]. Along the same lines, to date only two studies have reported the detection of a spiked antigen in cancer patient tissues using antibody-based FET [29,30] or memristor sensors [31]. In these Box 2.…”
Section: Protein Cancer Markersmentioning
confidence: 99%
“…studies, a spiked rabbit antigen was detected in the fM range in the presence of a 100 000-fold molar excess of non-specific human proteins [29][30][31]. The main limitations of nanowire sensors in detecting cancer markers in clinical specimens are the presence of salts that decrease the Debye length, the need for individual sensor calibration, and the multiplex capabilities of nanowire sensors which are so far limited to a maximum of three analytes.…”
Section: Protein Cancer Markersmentioning
confidence: 99%
“…Protein detection and investigation in various biological samples such as blood, serum, urine, and saliva is the center to disease diagnosis and treatment. In another report, Puppo et al (2014) used single NW-based FET to detected bioanalytes in exogenously added rabbit antigen (5-200 fM) in a human breast tumor extract (a much more complex environment). They fabricated Si NGs-FETs with highly uniform performance using a complementary metal-oxide semiconductor (CMOS) process on low pdoped silicon-on-insulator wafers (Fig.…”
Section: Silicon Nws-based Fet Biosensormentioning
confidence: 99%