2001
DOI: 10.1081/jlc-100104896
|View full text |Cite
|
Sign up to set email alerts
|

High Throughput Assay Method for the Quantitation of Trimetazidine in Human Plasma by Lc/Ms, With Selected Reaction Monitoring

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
20
0

Year Published

2001
2001
2017
2017

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 14 publications
(24 citation statements)
references
References 4 publications
1
20
0
Order By: Relevance
“…Min et al [6] reported a HPLC method coupled with a liquid-liquid extraction procedure for sample clean-up, which, unfortunately, was obviously not suitable for the study of bioequivalence due to the relatively higher LOQ (10 ng/mL). De Jager et al [7] developed a LC/MS-MS method, despite the claim of relative short turn-round time, avoiding the use of internal standard made some concern of reproducibility. Recently, Medvedovici et al [8] developed a LC/APCI-MS-MS method for the determination of trimetazidine, however, the application of tandem mass is relative high-cost and operationally complex.…”
Section: Introductionmentioning
confidence: 98%
“…Min et al [6] reported a HPLC method coupled with a liquid-liquid extraction procedure for sample clean-up, which, unfortunately, was obviously not suitable for the study of bioequivalence due to the relatively higher LOQ (10 ng/mL). De Jager et al [7] developed a LC/MS-MS method, despite the claim of relative short turn-round time, avoiding the use of internal standard made some concern of reproducibility. Recently, Medvedovici et al [8] developed a LC/APCI-MS-MS method for the determination of trimetazidine, however, the application of tandem mass is relative high-cost and operationally complex.…”
Section: Introductionmentioning
confidence: 98%
“…Several LC with mass spectrometric detection are available for the determination of TMZ in biological samples and bioequivalence study (de Jager et al 2001; Ding et al 2007; Jiao et al 2007a, 2007b; Medvedovici et al 2005; Wang et al 2007). These assays have adequate sensitivity within a relatively short analysis time.…”
Section: Discussionmentioning
confidence: 99%
“…The LOQ value was 0.4 ng/mL in a 0.5 mL plasma sample (Wang et al 2007). de Jager et al (2001) proposed a rapid, selective, and sensitive LC‐MS method for the determination of TMZ. The method was applied to the pharmacokinetic study of TMZ tablet dosage form.…”
Section: Discussionmentioning
confidence: 99%
“…Recently, chemiluminogenic reaction of TMZ with potassium permanganate was proposed for its assay in biological fluids (Palilis and Calokerinos 2000). LC-MS was reported only once as a quantitative tool for assaying TMZ from plasma samples (de Jager et al, 2001). The sample preparation procedure was based on liquid extraction of TMZ in hexane-dichloromethane followed by its derivatization with acetic anhydride.…”
Section: Trimetazidinementioning
confidence: 99%