2021
DOI: 10.1039/d1nr03996b
|View full text |Cite
|
Sign up to set email alerts
|

Highly efficient copper halide scintillators for high-performance and dynamic X-ray imaging

Abstract: Progress towards high performance X-ray detection and dynamic imaging applications, including nondestructive inspection, homeland security, and medical diagnostics, requires scintillators with high light yield, reasonable decay time, low cost, and...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
46
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 61 publications
(46 citation statements)
references
References 52 publications
0
46
0
Order By: Relevance
“…The light yields of these Cu-doped samples were assessed by the RL spectra comparison method with a commercially available LYSO single crystal (15 × 15 × 1 mm, 33 200 photons MeV −1 ) scintillator under identical measurement conditions. The light yield can be calculated using the following equation: 18 where η is the X-ray deposited energy percentage of the scintillator, I is the RL intensity at different wavelengths ( λ ), and S is the irradiation area. The X-ray dose rate was measured using an Accu-Gold diagnostic system (Radcal) equipped with an ionization chamber.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The light yields of these Cu-doped samples were assessed by the RL spectra comparison method with a commercially available LYSO single crystal (15 × 15 × 1 mm, 33 200 photons MeV −1 ) scintillator under identical measurement conditions. The light yield can be calculated using the following equation: 18 where η is the X-ray deposited energy percentage of the scintillator, I is the RL intensity at different wavelengths ( λ ), and S is the irradiation area. The X-ray dose rate was measured using an Accu-Gold diagnostic system (Radcal) equipped with an ionization chamber.…”
Section: Methodsmentioning
confidence: 99%
“…To assess the spatial resolution of this Cs 2 ZnBr 4 :Cu scintillation detector, a standard test-pattern plate (0.05 mm Pb) is used, and the Cs 2 ZnBr 4 :Cu screen achieves a spatial resolution of 9 lp mm −1 which is higher than the commercial CsI:Tl or a-Se flat panel detector (3-3.5 lp mm −1 at MTF = 0.2). [48][49][50] To further confirm the spatial resolution, the modulation transfer function (MTF) curve was measured by the slanted-edge method, 18,21 as shown in Fig. S14.…”
Section: X-ray Imagingmentioning
confidence: 99%
See 1 more Smart Citation
“…3a and b. Huang–Rhys factors ( S ) were further derived to compare the electron-phonon coupling strength in both crystals by using the following equation: 14,34 where FWHM is the full width at half maximum of photon energy, ℏ ω photon is the effective photon energy, k B is the Boltzmann constant, and T is the temperature. As shown in Fig.…”
Section: Resultsmentioning
confidence: 99%
“…3a and b. Huang-Rhys factors (S) were further derived to compare the electron-phonon coupling strength in both crystals by using the following equation: 14,34…”
Section: Intermolecular Forces Drive Perovskite Reconstruction With P...mentioning
confidence: 99%