2016
DOI: 10.1016/j.apsusc.2016.03.181
|View full text |Cite
|
Sign up to set email alerts
|

Hot corrosion behavior of Ni based Inconel 617 and Inconel 738 superalloys

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
44
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
3

Relationship

0
9

Authors

Journals

citations
Cited by 121 publications
(47 citation statements)
references
References 9 publications
2
44
0
1
Order By: Relevance
“…As an oxide phase mainly Cr 2 O 3 is detected together with some unidentified phase, with possible partial fit to the Laves phase family. These constitute a broad group of Cr‐Nb‐Si intermetallics, with several diffraction peaks from Figure possibly attributable to them . The amount of the Laves phase is not influenced by the amount of Y, that supports this explanation.…”
Section: Resultssupporting
confidence: 60%
“…As an oxide phase mainly Cr 2 O 3 is detected together with some unidentified phase, with possible partial fit to the Laves phase family. These constitute a broad group of Cr‐Nb‐Si intermetallics, with several diffraction peaks from Figure possibly attributable to them . The amount of the Laves phase is not influenced by the amount of Y, that supports this explanation.…”
Section: Resultssupporting
confidence: 60%
“…Nevertheless, the separation of substrate curves is higher in comparison with the other ones studied, reporting highest corrosion rates. On the other hand, the corrosion rate is very low for both systems (Three-layer Painting System and Thermal Spray System), generating a protection of zinc and aluminum pigments respectively; although there is a little consumption increase of current density in 2250 hours, for both systems, fact that raises zinc and aluminum consumption, forming oxides: The above phenomena are corroborated on the SEM images, leading to lose of paint adherence and an increment of rate corrosion [27][28][29][30][31][32][33].…”
Section: Figurementioning
confidence: 92%
“…Most of the high temperature degradation studies have been carried out in simulated environment [10][11][12][13][14][15][16][17][18][19] and very few in-situ studies on superalloys have been carried out in a medical waste incinerator. Hence the aim of present study is to evaluate the degradation behaviour of nickel-based superalloys Superni-75, Superni-750 and Superni-718 hung inside the secondary chamber of a medical waste incinerator at SKIMS Hospital, Soura, Jammu and Kashmir, India which is a tertiary care 600 bedded teaching hospital, catering to the average socioeconomic class.…”
Section: Introductionmentioning
confidence: 99%