2012
DOI: 10.1111/j.1708-8208.2012.00472.x
|View full text |Cite
|
Sign up to set email alerts
|

Human Cadaver Study Evaluating a New Measurement Technique for Graft Volumes after Sinus Floor Elevation

Abstract: The IRRA measurement technique can be recommended as a noninvasive tool to evaluate graft volumes in human maxillary sinuses.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 36 publications
0
7
0
Order By: Relevance
“…Platzer et al [11] used a non-commercial measurement technique based on the novel concept of an Interactive Rigid Registration Algorithm (IRRA). Parameters analyzed included the reproducibility of IRRA measurements and their reliability in comparison with the established measurement technique of RGST.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Platzer et al [11] used a non-commercial measurement technique based on the novel concept of an Interactive Rigid Registration Algorithm (IRRA). Parameters analyzed included the reproducibility of IRRA measurements and their reliability in comparison with the established measurement technique of RGST.…”
Section: Discussionmentioning
confidence: 99%
“…Nevertheless, resorption and remodeling of an autologous bone graft still remains a concern, as an imbalance between these processes may lead to insufficient bone volume and thereby frustrate implant placement [10]. Volumetric reduction of grafting material has been observed with autogenous bone grafts as well as synthetic bone substitute materials [11][12][13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Clinically, a BS should be easy to use, cost effective, and with adequate density to allow easy radiographic recognition during the entire healing process [27, 29]. This feature is particularly important to radiographically follow the rate of resorption/substitution [30, 31]. …”
Section: Introductionmentioning
confidence: 99%
“…Moreover, the algorithm developed in this study enabled determining the volume of the grafted area thereby reflecting the anatomical situation present clinically in a reproducible manner. There are a number of in vitro methods available for such volumetric measurements, all of which have a number of drawbacks in that they do not adequately take into account postoperative variability such as tissue responses of the Schneiderian membrane, air entrapment in the grafting material and others [35].…”
Section: Discussionmentioning
confidence: 99%