2017
DOI: 10.1109/jetcas.2017.2675879
|View full text |Cite
|
Sign up to set email alerts
|

Hybrid Controller for Wind Turbine Generators to Ensure Adequate Frequency Response in Power Networks

Abstract: Converter-interfaced power sources (CIPS) are hybrid control systems as they may switch between multiple operating modes. Due to increasing penetration, the hybrid behavior of CIPS, such as, wind turbine generators (WTG), may have significant impact on power system dynamics. In this paper, the frequency dynamics under inertia emulation and primary support from WTG is studied. A mode switching for WTG to ensure adequate frequency response is proposed. The switching instants are determined by our proposed concep… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
35
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 38 publications
(35 citation statements)
references
References 32 publications
0
35
0
Order By: Relevance
“…This supervisory control can not only generate switching commands, but also provide real-time margin for a critical safe switching. The works in [16], [17], [40], [41] have taken this advantages.…”
Section: Power System Applicationsmentioning
confidence: 99%
“…This supervisory control can not only generate switching commands, but also provide real-time margin for a critical safe switching. The works in [16], [17], [40], [41] have taken this advantages.…”
Section: Power System Applicationsmentioning
confidence: 99%
“…From the theoretic aspect 1) Based on the definition of region of safety (ROS) in [35], this paper formally defines the largest ROS (LROS), and interprets the relation between the true backward reachable set and the LROS. 2) Based on the occupation measure and corresponding formulations in [36], where the time-dependent backward reachable set is estimated, this paper modifies the formulation to calculate the invariant backward reachable set, and first provides the geometric interpretation.…”
Section: B Contributionsmentioning
confidence: 99%
“…2) Based on the occupation measure and corresponding formulations in [36], where the time-dependent backward reachable set is estimated, this paper modifies the formulation to calculate the invariant backward reachable set, and first provides the geometric interpretation. The introduction of this theory guarantees L-1 norm convergence to the true LROS as a significant improvement from the framework in [35].…”
Section: B Contributionsmentioning
confidence: 99%
See 1 more Smart Citation
“…Line impedance (pu) Line charging (pu) 2-8 (2)(3)(4)(5)(6)(7)(8)(9) j0.01 0.0006625 7-8 (7)(8)(9) j0.04 0.0023 4-8 (4)(5)(6)(7)(8)(9) j0.03 0.0031 4-5 j0.03 0.0034 5-6 j0.03 0.0094 6-7 j0.02 0.0258 of the stochastic robust neighbourhoods in the dimension of the grid frequency variationδ i * 1,1 (δ i * 1,1 =δ i * 1,2 =δ i * 2,1 =δ i * 2,2 ) are much smaller than the outer bounds in the dimension of the wind turbine rotor speed variationδ i * 1,3 (δ i * 1,3 =δ i * 1,4 ). Aŝ δ k,i = ( √ r q i + √γ )/z k,i andγ = 100M q 0 (3, 3), minimizinĝ δ 1,1 can be achieved by minimizing M q i (3, 3) (i = 1, 2, 3) and maximizing z i 1,1 .…”
Section: Line Numbermentioning
confidence: 99%