1998
DOI: 10.1016/s0039-9140(98)00122-2
|View full text |Cite
|
Sign up to set email alerts
|

Hydrogen ion-selective membrane electrodes based on alkyldibenzylamines as neutral carriers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
6
0
1

Year Published

2007
2007
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(7 citation statements)
references
References 12 publications
0
6
0
1
Order By: Relevance
“…The electrical resistance for the ionophore free membrane (electrode 1) was much lower than the resistance for the ionophore-containing membrane (electrode 4). On the contrary, it was stated in literature that the addition of neutral carriers such as alkyldibenzylamines had no effect on the electrical resistance of the membrane electrodes [24]. This behaviour may be attributed to the introduction of a huge neutral macrocyclic compound as calix [4]arene derivative to the membrane.…”
Section: Working Range and The Slope Of The Electrodementioning
confidence: 85%
See 2 more Smart Citations
“…The electrical resistance for the ionophore free membrane (electrode 1) was much lower than the resistance for the ionophore-containing membrane (electrode 4). On the contrary, it was stated in literature that the addition of neutral carriers such as alkyldibenzylamines had no effect on the electrical resistance of the membrane electrodes [24]. This behaviour may be attributed to the introduction of a huge neutral macrocyclic compound as calix [4]arene derivative to the membrane.…”
Section: Working Range and The Slope Of The Electrodementioning
confidence: 85%
“…4). The proposed electrode was found much more suitable than many of the other alternatives given in the literature as regard to the linear working range and slope [1,[6][7][8][9][10][11][12][13][14]16,[18][19][20][22][23][24][25]30,32,33]. The comparison of response characteristics of some different type of pH sensing electrodes together with the proposed electrode are given in Table 2.…”
Section: Working Range and The Slope Of The Electrodementioning
confidence: 91%
See 1 more Smart Citation
“…Ayr›ca, mikroelektrot olarak üretilmeye ve in situ (yerinde) çal›flmalarda kullan›lmaya uygun de¤ildirler (4,5). Bu nedenle, son y›llarda, kat›-temasl› elektrotlar (SCE'lar) (6)(7)(8)(9)(10)(11)(12), kaplanm›fl tel elektrotlar (CWE'lar) (13,14), alan etkili transistörler (FET'ler) (15,16), nano çubuk elektrotlar (17,18) ve polimerik membran elektrotlar (PME'lar) (19)(20)(21)(22)(23)(24)(25)(26)(27)(28)(29)(30)(31)(32)(33) (10,27,28), aminler (11)(12)(13)24), pillar [5]arenler (29), ve kaliks [4]arenler (30)(31)(32)(33) gösterilebilir. Literatür incelendi¤inde, baz› ilaç etken maddelerinin voltametrik/amperometrik sensörlerde duyarl›l›k sa¤lamak amac›yla kullan›ld›¤› (36, 37), ancak, pH duyarl› potansiyometrik PVC membran elektrot haz›rlanmas›nda iyonofor olarak kullan›lmad›¤› tespit edilmifltir.…”
Section: Introductionunclassified
“…Hydrogen ion selective elec trodes were also prepared using calixarene derivatives as neutral carriers such as 5,11,17,23 tetra tert butyl 25,26,27,28 tetracyanomethoxycalix[4]arene [10], calix [4] aza crowns [11], p tert butylcalix [4]arene oxacrown 4 [1], that all showed sensitivity at pH > 2. Some hydrogen ion selective membrane electrodes based on amines as neutral carriers were also prepared with similar pH sensitivity [12][13][14][15]. 1 The article is published in the original.…”
mentioning
confidence: 99%