2004
DOI: 10.1109/lpel.2004.828442
|View full text |Cite
|
Sign up to set email alerts
|

Identification of Grid Impedance for Purposes of Voltage Feedback Active Filtering

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
26
0

Year Published

2004
2004
2020
2020

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 37 publications
(26 citation statements)
references
References 4 publications
0
26
0
Order By: Relevance
“…Theoretical developments are given in [16], where its efficiency in fault detection and isolation of faulty sensor in electrical drives (FDI) was proven. Its principle consists on the calculation of the difference between two consecutive current measurements.…”
Section: Grid Impedance Variation Detectionmentioning
confidence: 99%
See 1 more Smart Citation
“…Theoretical developments are given in [16], where its efficiency in fault detection and isolation of faulty sensor in electrical drives (FDI) was proven. Its principle consists on the calculation of the difference between two consecutive current measurements.…”
Section: Grid Impedance Variation Detectionmentioning
confidence: 99%
“…The threshold expression is given by (8) where more analytical development is performed in [15], [16]. The parameters used for the threshold expression are given in Table 1.…”
Section: Grid Impedance Variation Detectionmentioning
confidence: 99%
“…In practice, the impedance information is of particular concern because it leads to interactions between the grid-connected power converters and the grid, which might cause the system resonance and instability (Sun, 2011). Aside from that, the impedance information is also essential for many other applications, such as power sources and conditioners design (Roberto, 2009), islanding detection (Ciobotaru et al, 2010), power flow control (Vasquez et al, 2009), passive filter design (Das, 2004), and active filter control (Tarkiainen et al, 2004).…”
Section: Introductionmentioning
confidence: 99%
“…Some literatures have been researched the stability criterion related to the grid impedance [7]- [9], and many robust current controls against grid impedance also have been proposed under an uncertainty condition that the grid impedance could not be measured [10]- [12]. To overcome the uncertainty, some researches have proposed grid impedance prediction methods [13]- [ 14]. However, the theoretical analysis and negative impact of the low order harmonics caused by the grid impedance have been reported rarely, and the compensating method to attenuate the impact of grid impedance not proposed yet.…”
Section: Introductionmentioning
confidence: 99%