2011
DOI: 10.1016/j.ijrobp.2010.05.052
|View full text |Cite
|
Sign up to set email alerts
|

Image-Guided Localization Accuracy of Stereoscopic Planar and Volumetric Imaging Methods for Stereotactic Radiation Surgery and Stereotactic Body Radiation Therapy: A Phantom Study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
53
2
1

Year Published

2014
2014
2022
2022

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 41 publications
(57 citation statements)
references
References 12 publications
1
53
2
1
Order By: Relevance
“…Despite a completely new linac and new treatment head design, Vero beam data characteristics are remarkably similar to those of other linacs operating at 6 MV 38 , 42 , 43 , 44 . Agreement between dosimetry measurement and calculation is exceptionally good, both in Solid Water and in a heterogeneous thorax phantom.…”
Section: Discussionmentioning
confidence: 66%
See 2 more Smart Citations
“…Despite a completely new linac and new treatment head design, Vero beam data characteristics are remarkably similar to those of other linacs operating at 6 MV 38 , 42 , 43 , 44 . Agreement between dosimetry measurement and calculation is exceptionally good, both in Solid Water and in a heterogeneous thorax phantom.…”
Section: Discussionmentioning
confidence: 66%
“…Ma et al (51) reported residual RMS errors from 0.17 to 0.30 mm (σ from 0.17 to 0.29 mm) for stereotactic X‐ray localization and 0.35 to 0.50 mm (σ from 0.33 to 0.48 mm) for CBCT localization. Kim et al (38) reported average errors from 0.2 to 0.8mm (σ from 0.2 to 0.4 mm) for stereotactic X‐ray localization and 0.0 to 0.6 mm (σ from 0.5 to 0.7 mm) for CBCT localization. While wider error distributions were observed for CBCT localization in both studies, differences between the two methodologies did not reach statistical significance.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Treatment delivery methods have advanced to further improve conformality to complex geometric targets, while limiting dose to critical organs, such as dynamic conformal arc (DCA), Intensity Modulated Radiation Therapy (IMRT), and Volumetric Modulated Arc Therapy (VMAT) 13 , 14 , 15 , 16 . In the era of image guidance, numerous methods have been developed for stereotactic treatment delivery, including optical surface monitoring, in‐room CT, stereoscopic X‐ray imaging, ultrasound, and cone‐beam computed tomography (CBCT) 17 , 18 , 19 , 20 . Image‐guided frameless treatment has been systematically studied and the positioning accuracy has been validated for use in stereotactic treatments 20 , 21 …”
Section: Introductionmentioning
confidence: 99%
“…In the era of image guidance, numerous methods have been developed for stereotactic treatment delivery, including optical surface monitoring, in‐room CT, stereoscopic X‐ray imaging, ultrasound, and cone‐beam computed tomography (CBCT) 17 , 18 , 19 , 20 . Image‐guided frameless treatment has been systematically studied and the positioning accuracy has been validated for use in stereotactic treatments 20 , 21 …”
Section: Introductionmentioning
confidence: 99%