2021
DOI: 10.1007/s11696-021-01646-3
|View full text |Cite
|
Sign up to set email alerts
|

In-line monitoring of sitagliptin dissolution profile from tablets utilizing an eco-friendly potentiometric sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 20 publications
(11 citation statements)
references
References 42 publications
0
11
0
Order By: Relevance
“…Nowadays, the environment protection and the personal health and safety are considered in the eld of chemistry, that led to increasing number of published articles about how to work according to green principles and guidelines to obtain better clean handling of chemistry 17 . GAC has been considered in different techniques such as spectrophotometry 18 , spectro uorimetry 19 , electrochemistry 20 and chromatography 21 . The methods for evaluating greenness of an analytical method should be quantitative, and consistent evaluating methods.…”
Section: Ibuprofen (Ibu) (2rs)-2-[4-(2-methylpropylmentioning
confidence: 99%
“…Nowadays, the environment protection and the personal health and safety are considered in the eld of chemistry, that led to increasing number of published articles about how to work according to green principles and guidelines to obtain better clean handling of chemistry 17 . GAC has been considered in different techniques such as spectrophotometry 18 , spectro uorimetry 19 , electrochemistry 20 and chromatography 21 . The methods for evaluating greenness of an analytical method should be quantitative, and consistent evaluating methods.…”
Section: Ibuprofen (Ibu) (2rs)-2-[4-(2-methylpropylmentioning
confidence: 99%
“…Electrochemical methods are considered inherently green techniques through the use of water and buffers as the main solvents. Moreover, potentiometric measurements are time and cost-effective, besides being simple with very few sample pre-treatment steps [ 7 – 10 ].…”
Section: Introductionmentioning
confidence: 99%
“…[27,28] Due to the significance of potentiometric sensors for sitagliptin analysis, some conventional polymeric liquid membrane electrodes have been introduced for this drug. [29][30][31][32] Nevertheless, all of these reported electrodes were prevalent liquid membrane electrodes with an internal solution, which inherently contains drawbacks like less mechanical stability, more ohmic resistance and higher detection limit because of concentration diffusion through the membrane from the internal solution side. [33] These disadvantages restrict the practical application of these liquid membrane electrodes to determine low-level detection of SG in different real samples having a concentration lower than micromolar.…”
Section: Introductionmentioning
confidence: 99%