2016
DOI: 10.11607/ijp.4769
|View full text |Cite
|
Sign up to set email alerts
|

In Vitro Cyclic Dislodging Test on Retentive Force of Two Types of Female Parts of SFI-Bar

Abstract: This study aimed to compare the difference in mechanical behavior between two types of female-part clips of the Stress-Free Implant Bar (SFI-Bar) system during simulation of insertion-removal cycles. Materials and Methods: A total of 10 samples simulating SFI-Bar-attachment-retained implant overdentures were fabricated and randomly divided into two groups (n = 5). One group used E-clips (Elitor alloy) as the female part of the SFI-Bar, and the other used T-clips (all titanium grade IV with red nylon inserts). … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
12
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(14 citation statements)
references
References 5 publications
1
12
0
Order By: Relevance
“…Also casting or soldering the Hader bar may reduce the length of the retentively usable bar surfaces 27 , while the entire length of SFI bar may be used to increase the retention. The increased retention of the SFI bar was in line with findings of another study 24 in which the authors used plastic clips over the SFI bar and found that these clips maintain retention and need replacement after 2 to 3 years of clinical use. Also, Kobayashi, et al 26 noted that SFI-Bar exhibit higher retentive capacities than the Locatorattachment over time.…”
Section: Discussionsupporting
confidence: 86%
See 2 more Smart Citations
“…Also casting or soldering the Hader bar may reduce the length of the retentively usable bar surfaces 27 , while the entire length of SFI bar may be used to increase the retention. The increased retention of the SFI bar was in line with findings of another study 24 in which the authors used plastic clips over the SFI bar and found that these clips maintain retention and need replacement after 2 to 3 years of clinical use. Also, Kobayashi, et al 26 noted that SFI-Bar exhibit higher retentive capacities than the Locatorattachment over time.…”
Section: Discussionsupporting
confidence: 86%
“…This bar connects implants with no soldering or laserwelding. This allows construction of a passive-fit bar 24 with reduced corrosion 25 . Moreover, this bar can be used with individual implant angulations up to 15°2 6 .…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…This bar connects implants with no soldering or laserwelding. This allows construction of a passive-fit bar 17 with reduced corrosion 18 . Moreover, this bar can be used with individual implant angulations up to 15°1 9 .…”
Section: Locator Versus Stress Free Implant Bar Attachments For Two -Implants Immediately Loaded By Mandibular Overdentures a One Year Ramentioning
confidence: 99%
“…It can be adjusted to variable interimplant distance. The bar is supplied with 2 types of female part, the E-clips (Elitor precious metal alloy) and the T-clips (all titanium grade IV with nylon inserts) 17 . Despite these several advantages, the success of SFI bar needs to be investigated in clinical studies 19 .…”
Section: Locator Versus Stress Free Implant Bar Attachments For Two -Implants Immediately Loaded By Mandibular Overdentures a One Year Ramentioning
confidence: 99%