2017
DOI: 10.1111/ocr.12156
|View full text |Cite
|
Sign up to set email alerts
|

In vitro evaluation of the influence of velocity on sliding resistance of stainless steel arch wires in a self‐ligating orthodontic bracket

Abstract: At very low SV and low normal forces, SV influences the RS of SS archwires in orthodontic brackets, and the proportionality is logarithmic. Although respecting these parameters in vitro is challenging, quantitative evaluations of RS should be carried out at clinically relevant velocities if aiming at translational application in the clinical scenario.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
17
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 16 publications
(19 citation statements)
references
References 32 publications
2
17
0
Order By: Relevance
“… 66 Nevertheless, the testing temperature was reported by only a few studies. Furthermore, although the sliding velocity was usually mentioned (89%), previous studies showed variations in RS at different velocities 35 36 67 and it is noteworthy that the values reported, e.g., up to 20 mm/min, 36 68 were far from clinical orthodontic movements by several orders of magnitude. This being said, the bonding material was not considered even though resin composite luting cement, 69 cyanoacrylate cement, 9 70 and epoxy resin 32 may exhibit different elasticities that influence bracket movement.…”
Section: Discussionmentioning
confidence: 91%
See 1 more Smart Citation
“… 66 Nevertheless, the testing temperature was reported by only a few studies. Furthermore, although the sliding velocity was usually mentioned (89%), previous studies showed variations in RS at different velocities 35 36 67 and it is noteworthy that the values reported, e.g., up to 20 mm/min, 36 68 were far from clinical orthodontic movements by several orders of magnitude. This being said, the bonding material was not considered even though resin composite luting cement, 69 cyanoacrylate cement, 9 70 and epoxy resin 32 may exhibit different elasticities that influence bracket movement.…”
Section: Discussionmentioning
confidence: 91%
“…73 In fact, only a few studies attempted to quantify the ligation force in standard brackets. 74 Regarding SL brackets, although in ASL and IASL brackets the force of the closure system can be measured through the constant of elasticity of the clip, 67 comparisons between different types of brackets are still challenging. Lastly, in agreement with their definition, PSL brackets have no active component and thus no normal force is generated by the ligating system of the bracket.…”
Section: Discussionmentioning
confidence: 99%
“…[35,36] It is a well-known fact that the archwires size can affect sliding of teeth during space closure. [50] The highest canine retraction rate (MD; 0.76 mm /month) was reported by Aksakalli [35] but with a very wide confidence interval of 95% (0.19-1.34 mm / month). This wide confidence interval lowers the precision in the point of estimate and increases uncertainty about the intervention estimate in that study.…”
Section: Plos Onementioning
confidence: 92%
“…surgical implements and implants, and in dentistry, e.g. abutment, prostheses and orthodontic wires [ 2 ]. In particular, study [ 3 ] has shown Ti-made hip balls and sockets (as a joint replacement) could stay in patients’ body for more than 20 years.…”
Section: Introductionmentioning
confidence: 99%