1988
DOI: 10.1016/0360-3016(88)90026-0
|View full text |Cite
|
Sign up to set email alerts
|

Intraoperative radiation therapy of hepatic metastases: Technical aspects and report of a pilot study

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
9
0
4

Year Published

1990
1990
2009
2009

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(13 citation statements)
references
References 5 publications
0
9
0
4
Order By: Relevance
“…First, IORT is an open procedure with significant invasiveness and procedurerelated comorbidity. Second, administering the radiation dose in the target volume is hampered by the fact that applicator placement is guided either by manual palpation or sonographic monitoring [19,20] . In this situation, neither adequate coverage of the target volume fraction nor exact sparing of adjacent critical tissue such as hepatic reserve capacity, bile duct or intestine can be guaranteed.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…First, IORT is an open procedure with significant invasiveness and procedurerelated comorbidity. Second, administering the radiation dose in the target volume is hampered by the fact that applicator placement is guided either by manual palpation or sonographic monitoring [19,20] . In this situation, neither adequate coverage of the target volume fraction nor exact sparing of adjacent critical tissue such as hepatic reserve capacity, bile duct or intestine can be guaranteed.…”
Section: Introductionmentioning
confidence: 99%
“…The typical doses applied ranged from 15 to 30 Gy with reference to the tumor margin. The brachytherapy technique generally leads to a high dose inhomogeneity in the target volume [14][15][16][17][18] . However, the intraoperative approach has some drawbacks.…”
Section: Introductionmentioning
confidence: 99%
“…This technique was developed in the late 1980s in an attempt to combine the technical and dosimetric advantages of brachytherapy with the conceptual and logistic advantages of IOERT [8][9][10][11][12][13][14][15][16]. Although HDR remote after loaders were initially utilized in 1964 and have become common in modern radiation oncology departments, they have been used primarily in the outpatient setting.…”
Section: Experiences In Hdr-iortmentioning
confidence: 99%
“…Prinzipiell befürchten wir für dieses Vorgehen erhöhte Fehlertoleranzen. Dritschilo et al [8] beschreiben Ergebnisse einer Studie an elf Patienten unter Nutzung einer 192 Ir-Brachytherapie zur Einzeitbestrahlung mit angestrebten minimalen 20 Gy. Die Anzahl behandelter Lebermetastasen variierte zwischen zwei und elf mit Durchmessern zwischen 3 und 9 cm (Median: 6 cm).…”
Section: Diskussionunclassified
“…Die angegebenen Dosen variieren zwischen minimal 15 und 30 Gy mit erheblichen Dosisinhomogenitäten innerhalb des Tumorvolumens [8,29]. Nachteile des intraoperativen Ansatzes sind die Notwendigkeit der Laparotomie mit einer erheblichen Komorbidität und eine unzulängliche Dosimetrie nach palpatorischer oder sonographisch geführter Platzierung der Katheter [8].…”
Section: Introductionunclassified