2020
DOI: 10.1080/19440049.2020.1853821
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of chocolate types on the content of selected metals and non-metals determined by ICP-OES analytical technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

10
12
1

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(23 citation statements)
references
References 17 publications
10
12
1
Order By: Relevance
“…After heating to 765 °C (~85 s), the AAS did not measure any Cd signal in Figure 2 , proving no breakthrough of Cd into the detector. This is in accordance with the previous result [ 22 ] that a small fraction of Cd analyte was pre-vaporized and then trapped by the pyrolysis filler. As shown in Figure 2 , the Cd signals under more than 700 °C indicate a plateau with 4–7% RSDs, proving that MgO filler also fulfills the retention of re-vaporized Cd for the following vaporization and release processes under a N 2 /H 2 mixture atmosphere.…”
Section: Resultssupporting
confidence: 93%
See 1 more Smart Citation
“…After heating to 765 °C (~85 s), the AAS did not measure any Cd signal in Figure 2 , proving no breakthrough of Cd into the detector. This is in accordance with the previous result [ 22 ] that a small fraction of Cd analyte was pre-vaporized and then trapped by the pyrolysis filler. As shown in Figure 2 , the Cd signals under more than 700 °C indicate a plateau with 4–7% RSDs, proving that MgO filler also fulfills the retention of re-vaporized Cd for the following vaporization and release processes under a N 2 /H 2 mixture atmosphere.…”
Section: Resultssupporting
confidence: 93%
“…These above methods demonstrate high sensitivity and good accuracy; however, they are complicated, have high power consumption, and fail to render the rapid detection of Cd in food samples due to acid digestion and liquid sampling procedures regardless of toxic reagent consumption and environmental contamination. Additionally, chocolate is rich in cocoa butter, in which the lipid components are difficult in being completely digested via the regular digestion method [ 22 ]. Thus, it is necessary to establish a rapid analysis method of Cd in chocolate without the digestion process.…”
Section: Introductionmentioning
confidence: 99%
“…Dry samples of roots and leaves were digested as described earlier (Oleńska et al, 2020b). After digestion, the samples were diluted (Karaś et al, 2021), and an ICPE-9820 (Shimadzu, Kyoto, Japan) with a mini-torch was used for the qualitative and quantitative detection of elements (Zn, Pb, Cd). Prior to analysis, the Sigma-Aldrich (St. Louis, MO, United States) periodic table mix 1 for ICP containing 10-mg L −1 of Zn, Pb, and Cd in 10% nitric acid (comprising HF traces) was used for calibration of the ICP-OES (inductively coupled plasma optical emission spectrometry).…”
Section: Metal Concentrations In Trifolium Repens Leaves and Rootsmentioning
confidence: 99%
“…It was observed that the minerals content in the lupin-based chocolate dessert formulations increased, except for Ca, with the increase in the substitution ratio. This behavior could be explained by the fact that the dark chocolate is rich in P (2324 mg/kg), K (3651 mg/kg), Mg (1564 mg/kg), Fe (479 mg/kg), and Zn (105 mg/kg) (Jácimovíc et al, 2022;Karas et al, 2021;Grassia et al, 2019), and this content was higher than that of the lupin milk. Since the Ca content of the dark chocolate was about 908 mg/kg (Jácimovíc et al, 2022) which was lower than that of the lupin milk, therefore the content of Ca in the lupin-based chocolate dessert formulations decreased with increasing the substitution ratio.…”
Section: Major and Trace Elementsmentioning
confidence: 99%