2013
DOI: 10.1016/j.ijleo.2013.06.010
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of positioning algorithm and method for increasing the linear measurement range for four-quadrant detector

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
19
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 44 publications
(19 citation statements)
references
References 8 publications
0
19
0
Order By: Relevance
“…11); its center should align to the center of AUV; its sensitive plane should directly face the front of AUV. Chen et al (2013) and Hao et al (2012) recommend that when the size of light spot on the sensitive plane is half of the quadrant detector's sensitive area, the optical system has the best performance. To make the optical system work normally, a convex lens is fixed in front of the detector.…”
Section: Optical Quadrant Detectormentioning
confidence: 99%
“…11); its center should align to the center of AUV; its sensitive plane should directly face the front of AUV. Chen et al (2013) and Hao et al (2012) recommend that when the size of light spot on the sensitive plane is half of the quadrant detector's sensitive area, the optical system has the best performance. To make the optical system work normally, a convex lens is fixed in front of the detector.…”
Section: Optical Quadrant Detectormentioning
confidence: 99%
“…For the improved new estimation method, only one parameter effective radius is introduced. Compared with the method mentioned in Reference [ 24 ], the new method has less parameters, which are more suitable for practical applications.…”
Section: Resultsmentioning
confidence: 99%
“…The traditional direct detection method, as described previously in References [4,6,7], is shown in Figure 2. As we can see in Figure 2, the four output electrical signals are sent to low pass filters (LPF) first.…”
Section: Direct Detection Methodsmentioning
confidence: 99%
“…Dang and colleagues analyzed the characteristics of the detector output signal [6]. The estimated spot position values and the real spot position values were calibrated by Chen and colleagues, the calibrated values then fitted to the polynomial [7]. This method is similar to the Boltzmann function method, the main difference being the greater complexity of the function employed in the method proposed by Chen and colleagues.…”
Section: Introductionmentioning