2020
DOI: 10.5505/pajes.2019.00334
|View full text |Cite
|
Sign up to set email alerts
|

Investigation of the effect of outdoor temperature data on the building heating energy requirement and validity of the TS 825 degree-day region clustering

Abstract: Dış sıcaklık verisi, binaların enerji gereksinimi hesaplamasını etkileyen en önemli parametrelerden biridir. Hacimsel ısıtma ağırlıklı enerji tüketiminin görüldüğü Türkiye'de, binaların ısı yalıtımı tasarımının yapılması ve ısıtma enerji ihtiyacının hesaplanması, TS 825 "Binalarda Isı Yalıtım Kuralları" standardına göre yapılmaktadır. TS 825'te, iller, sahip oldukları iklimsel koşullara göre derece-gün bölgelerinde (DGB) kümelendirilmektedir. Bu DGB'leri birbirinden ayıran temel iklimsel parametre ise dış sıca… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
1
0
2

Year Published

2021
2021
2022
2022

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 12 publications
0
1
0
2
Order By: Relevance
“…For life cycle emissions assessment (LCEA), emissions to be generated by energy consumption for the long term are calculated. The life cycle emission assessment calculation equation is [11],…”
Section: Electricity Consumption and Life Cycle Emissions Assessment ...mentioning
confidence: 99%
See 1 more Smart Citation
“…For life cycle emissions assessment (LCEA), emissions to be generated by energy consumption for the long term are calculated. The life cycle emission assessment calculation equation is [11],…”
Section: Electricity Consumption and Life Cycle Emissions Assessment ...mentioning
confidence: 99%
“…In the study, the effectiveness of insulation application according to TS 825 was investigated in two different processes short-term (savings in annual heating energy need, additional insulation cost and additional greenhouse gas emission) and life cycle (life cycle cost and greenhouse gas emission). In addition, the payback periods of the additional investment made in terms of cost and greenhouse gas were also analysed [11]. Cristina et al examined the impact of Carbon Capture and Storage units on the environmental, energy and economic performance of Brazilian electricity generation.…”
Section: Introductionmentioning
confidence: 99%
“…It was stated in the results that there would be a decrease in the heating day degree number and an increase in the cooling day degree numbers across the entire country. The study by Altun et al, 2020 examined the impact of outer temperature data on the building heating energy need and the validity of degree day regions formed in standard. The heating energy need of a sample building was calculated according to different outer temperature data of cities and degree day regions in force and the suggested version and compared for 81 provinces.…”
Section: Introductionmentioning
confidence: 99%
“…Binalarda enerji verimliliği, enerji performansı ile konfor seviyesinin ilişkilendirilmesi üzerine yapılmış pek çok çalışma mevcuttur [4,5,. Türkiye'de TS 825 [36]'in zorunlu hale gelmesi ile binalarda enerji performansı çalışmaları başlamıştır [37][38][39][40][41][42][43][44].…”
Section: Introductionunclassified
“…EnergyPlus[45], ANSI/ASHRAE 140[49] doğrulamasına sahiptir.DesignBuilder[50], bir Energy Plus[45] ara yüzeyi olarak hesaplamalarda kullanılmaktadır. DesignBuilder yazılımının veritabanında Energy Plus[44] (epw) formatında İzmir, İstanbul ve Ankara için saatlik meteorolojik veriler mevcuttur. Erzurum'a ait saatlik veriler ise Meteonorm (v.5.1x, 2019)[51] yazılımından epw formatında alınarak DesignBuilder iklim veritabanına aktarılmıştır.Tablo 3.…”
unclassified