Investigation of the Long- and Medium-Term Drift of Zener Diode-Based Voltage Standards

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 16 publications
0
5
0
Order By: Relevance
“…Self-heating in Zener diodes is a matter of concern and should be dealt with accordingly [12] where temperature drift is confirmed. This results in variations in reverse breakdown voltages, and [13] showed that drift is a problem in the medium-and long-term. Long-term stability stress testing revealed that there can be a shift in Zener voltage over time [1].…”
Section: Literature Studymentioning
confidence: 99%
“…Self-heating in Zener diodes is a matter of concern and should be dealt with accordingly [12] where temperature drift is confirmed. This results in variations in reverse breakdown voltages, and [13] showed that drift is a problem in the medium-and long-term. Long-term stability stress testing revealed that there can be a shift in Zener voltage over time [1].…”
Section: Literature Studymentioning
confidence: 99%
“…Ref. [9] proposes mathematical models for the long-and medium-term drift of voltage standards as well as measurements on four different commercial standards, namely, Fluke 732A, Fluke 732B, Datron 4910, and Guildline 4410. Measurement values were taken in an annual comparison over a period of 10 years.…”
Section: Introductionmentioning
confidence: 99%
“…Although the new SI base unit definitions are now in effect, the conventional method of establishing a voltage standard using the Josephson voltage device and the quantum Hall effect will continue from a practical point of view after adjusting the numerical values of the von Klitzing constant and Josephson constant from their 1990 values [1,2]. The Zener voltage standards are the most stable transfer standards to disseminate the DC voltage (DCV) standard from the National Metrology Institute (NMI) to NMI or calibration laboratories [3]. In addition, laboratory accreditation bodies require calibration laboratories to justify their calibration and measurement capability (CMC) based on proper calibration intervals of their systems according to standards documents [4,5].…”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, the Korea Laboratory Accreditation Scheme recommends one year as the calibration interval of the devices. This provisional calibration interval could be justified by statistical methods for devices of which the behaviours are predictable [3,10]. However, it is a challenge to establish the initial calibration interval of devices with no calibration record.…”