Iodide-selective polymeric membrane electrode based on copper(II) bis(N-2-bromophenylsalicyldenaminato) complex

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
3
0
2

Year Published

2012
2012
2017
2017

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(5 citation statements)
references
References 16 publications
0
3
0
2
Order By: Relevance
“…However, using the acetate buffer is favored as it showed more stable and reproducible results which can be ascribed to the absence of hydroxide as the strongest interfering anion especially for iodide sensing 5. Moreover, we detected the different response characteristics at very low pH value (2.0) using phosphate buffer in order to minimize the hydroxide interference to the lowest value.…”
Section: Resultsmentioning
confidence: 96%
See 1 more Smart Citation
“…However, using the acetate buffer is favored as it showed more stable and reproducible results which can be ascribed to the absence of hydroxide as the strongest interfering anion especially for iodide sensing 5. Moreover, we detected the different response characteristics at very low pH value (2.0) using phosphate buffer in order to minimize the hydroxide interference to the lowest value.…”
Section: Resultsmentioning
confidence: 96%
“…The selectivity manner of these sensors towards anions is found to be influenced by the steric effect related with the structure of ligands and the properties of the central metal ions 2–4 where a direct interaction occurs between the central metal of the membrane active components and the analyte anion. Several iodide selective electrodes have been reported in literature based on various metal complexes such as Cu 2+ 5, Hg 2+ , Cd 2+ 6, Ti 4+ 7, Co 3+ 8, Zn 2+ 9, Co 2+ 10, Fe 3+ 11, Mn 3+ 12, Ni 2+ 13, and Fe 2+ 14 in various matrices including polyvinyl chloride and carbon paste. To the best of our knowledge, there is only one published paper on the use of screen printed electrode for iodide determination 15.…”
Section: Introductionmentioning
confidence: 99%
“…Potansiyometrik yöntem, bu yöntemlerle kıyaslandığında, daha kısa analiz süresi, ekonomik olma, elektrotların kolay hazırlanabilmesi, kullanım pratikliği ve numunenin özelliğini bozmadan doğrudan ölçüm yapılabilmesi gibi pek çok açıdan üstünlük sağlayarak dikkatleri üzerine çekmektedir [17]. Bu amaçla kullanılacak iyon-seçici elektrotların (ISE) hazırlanmasında uzun yıllardır poli(vinil klorür)ün (PVC) destek malzemesi olarak kullanıldığı iç dolgu çözeltili PVC membran elektrotlar genellikle tercih edilmektedir [18].…”
Section: Introductionunclassified
“…Ancak, yaşam için gerekli bir element olan iyot, yüksek dozda alındığında zehirli etki göstermektedir. Örneğin; iyot buharına maruz kalan kişilerin gözleri ve akciğerleri tahriş olabilir [1,2]. Bazı ilaçlarda da iyot veya iyodür bulunmaktadır [3,4].…”
Section: Introductionunclassified