2009
DOI: 10.1016/j.apradiso.2008.07.012
|View full text |Cite
|
Sign up to set email alerts
|

Irradiation and dosimetry of Nitinol stent for renal artery brachytherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
3
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 17 publications
0
3
0
Order By: Relevance
“…In or der to im prove the qual ity of PET im ages by acquir ing high count and short du ra tion trans mis sion scans, the pos i tron emit ter 48 V (T 1/2 = 15.97 d; b+ de cay 50% and g-line: 944.13, 983.52, and 1312.10 keV) [2] that can be pre sented by many PET cy clo trons, is an in ter est ing can di date for PET im ag ing [2][3][4][5][6]. 48 V is fre quently used in nu clear med i cine; for ex am ple, the 48 V ra dio ac tive stent was pro duced by a nickel-ti ta nium stent ir ra di a tion with the pro ton beam, and the ef fi cacy of ra dio ac tive stent for ap pli ca tion in re nal ar tery brachytherapy was stud ied [7].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In or der to im prove the qual ity of PET im ages by acquir ing high count and short du ra tion trans mis sion scans, the pos i tron emit ter 48 V (T 1/2 = 15.97 d; b+ de cay 50% and g-line: 944.13, 983.52, and 1312.10 keV) [2] that can be pre sented by many PET cy clo trons, is an in ter est ing can di date for PET im ag ing [2][3][4][5][6]. 48 V is fre quently used in nu clear med i cine; for ex am ple, the 48 V ra dio ac tive stent was pro duced by a nickel-ti ta nium stent ir ra di a tion with the pro ton beam, and the ef fi cacy of ra dio ac tive stent for ap pli ca tion in re nal ar tery brachytherapy was stud ied [7].…”
Section: Introductionmentioning
confidence: 99%
“…Pro duc tion of 48 V by nat u ral ti ta nium, has been stud ied via the nat Ti(p, xn) [2][3][4][5][6][7][8][9], nat Ti(d, xn) [4] and nat Ti(a, xn) [10] re ac tions. The nat Ti(p, xn) 48 V re ac tion is suit able for me dium to low-en ergy cy clo trons.…”
Section: Introductionmentioning
confidence: 99%
“…However, it has the longest half-life (16 d) among all discussed β+γ candidates, suitable for the studies of slow metabolic processes and for the labelling of organic compounds (Qaim, 2011). The prospects of 48 V were recently reminded by Usman et al, 2017 as it is already finding applications as a tracer in biological actions in plants (Xuam Tham et al, 2001), in material science (Rorat et al, 2005) or in the renal artery brachytherapy (Arbabi et al, 2009). As suggested by Martin et al, 1995 it is also a promising candidate for the coincidence PET.…”
mentioning