2011
DOI: 10.1016/j.bios.2011.04.045
|View full text |Cite
|
Sign up to set email alerts
|

Label-free, chemiresistor immunosensor for stress biomarker cortisol in saliva

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
69
0
3

Year Published

2014
2014
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 104 publications
(72 citation statements)
references
References 17 publications
0
69
0
3
Order By: Relevance
“…26,27 The sensitivity of the biosensor is a critical parameter since the biomarkers in saliva are usually present at very low concentration. 28 Compared to other FET biosensors, the diameter of a silicon nanowire (SiNW) is comparable to the dimensions of many biological relevant molecules, offering an opportunity for efficient bioaffinity and high sensitivity in detecting biomarkers. 29 Again, thanks to the SiNW very small dimension, the SiNW obtains a high surface-to-volume ratio, allowing the SiNW FET biosensor to be a very sensitive tool for biomolecule detection.…”
Section: Introductionmentioning
confidence: 99%
“…26,27 The sensitivity of the biosensor is a critical parameter since the biomarkers in saliva are usually present at very low concentration. 28 Compared to other FET biosensors, the diameter of a silicon nanowire (SiNW) is comparable to the dimensions of many biological relevant molecules, offering an opportunity for efficient bioaffinity and high sensitivity in detecting biomarkers. 29 Again, thanks to the SiNW very small dimension, the SiNW obtains a high surface-to-volume ratio, allowing the SiNW FET biosensor to be a very sensitive tool for biomolecule detection.…”
Section: Introductionmentioning
confidence: 99%
“…Thanks to their high conductivity and large surface-to-volume ratio, small changes on the conformation or displacement of the immobilized bioreceptors can be detected (243,244). This transduction mechanism has been reported in field-effect transistors (FET) (2,69,245,246) and may provide the basis of future devices like sensor-based bioelectronic noses and tongues (114,236,247), although, at present, the response patterns obtained by these devices are not stable over time (2).…”
Section: Applications Of Carbon Nanotubes and Graphene In Biomedical mentioning
confidence: 99%
“…Their physical properties are strongly dependent on the way that graphitic sheets are wrapped to form the tubes (chirality), causing them to exhibit metallic or semiconducting characteristics [99]. In particular, SWCNTs have been explored as promising building blocks in the construction of FET-based immunosensors with improved sensibility [58,69,76,[80][81][82]103]. SWCNTs display high electron transfer because all carbon atoms are present in their surface.…”
Section: Carbon Nanotubesmentioning
confidence: 99%
“…Therefore, the displacement represents a successful strategy for detecting such target analytes. For example, Tliti et al described a label-free FET immunosensor based on SWCNT for the ultrasensitive detection of stress biomarker cortisol in saliva [82]. SWCNTs were covalently functionalized with a cortisol analog (cortisol-3-CMO-NHS ester) followed by covalent conjugation with monoclonal anti-cortisol antibodies (large size and charged proteins).…”
Section: Carbon Nanotubesmentioning
confidence: 99%
See 1 more Smart Citation